农药废水%COD%TOC%相关性
農藥廢水%COD%TOC%相關性
농약폐수%COD%TOC%상관성
pesticide wastewater pesticide wastewater pesticide wastewater%COD%TOC%relevance
针对农药厂高、中、低浓度的三类废水,测定其COD与TOC,并对测定值进行一元线性回归分析。结果表明,有机物成分稳定的废水不管浓度高低其COD与TOC均具有显著的相关性,可以建立相应的回归模型,模型计算值与测定值相对偏差小于5%。
針對農藥廠高、中、低濃度的三類廢水,測定其COD與TOC,併對測定值進行一元線性迴歸分析。結果錶明,有機物成分穩定的廢水不管濃度高低其COD與TOC均具有顯著的相關性,可以建立相應的迴歸模型,模型計算值與測定值相對偏差小于5%。
침대농약엄고、중、저농도적삼류폐수,측정기COD여TOC,병대측정치진행일원선성회귀분석。결과표명,유궤물성분은정적폐수불관농도고저기COD여TOC균구유현저적상관성,가이건립상응적회귀모형,모형계산치여측정치상대편차소우5%。
The value of COD and TOC in pesticide organic wastewater was measured, including high, medium and low concentration. Unary linear regression analysis was carried out according to the above measured value. It proved that COD and TOC had the significant correlation if organic matter composition was stable, regardless of high or low concentration. The corresponding regression model can be established, the relative deviation between calculated values by the model and measured values was less than 5%.