暖通空调
暖通空調
난통공조
HEATING,VENTILATING & AIR CONDITIONING
2015年
2期
98-101
,共4页
空气源热泵%冷却塔%水环热泵%负荷计算%运行策略%经济分析
空氣源熱泵%冷卻塔%水環熱泵%負荷計算%運行策略%經濟分析
공기원열빙%냉각탑%수배열빙%부하계산%운행책략%경제분석
air-source heat pump%cooling tower%water-loop heat pump%load calculation%operation strategy%economic analysis
结合上海一实际工程,介绍了一种空气源热泵+空气源热泵热回收机组+冷却塔+水环热泵系统的室内外计算参数、负荷计算、设备选用、运行策略。经济性分析表明该系统运行费用低于传统空气源热泵系统和水冷多联机+燃气锅炉系统。
結閤上海一實際工程,介紹瞭一種空氣源熱泵+空氣源熱泵熱迴收機組+冷卻塔+水環熱泵繫統的室內外計算參數、負荷計算、設備選用、運行策略。經濟性分析錶明該繫統運行費用低于傳統空氣源熱泵繫統和水冷多聯機+燃氣鍋爐繫統。
결합상해일실제공정,개소료일충공기원열빙+공기원열빙열회수궤조+냉각탑+수배열빙계통적실내외계산삼수、부하계산、설비선용、운행책략。경제성분석표명해계통운행비용저우전통공기원열빙계통화수랭다련궤+연기과로계통。
With a project in Shanghai,presents the indoor and outdoor air design conditions,load calculation,equipment selection and operation strategy of the system which consists of air-source heat pump,air-source heat pump heat recovery unit,cooling tower and water-loop heat pump.Economic analysis shows that this system has lower operation cost than that of traditional air-source heat pump system and water cooling VRF combined with gas boiler system.