加热炉冷却水管%断裂原因%改进措施
加熱爐冷卻水管%斷裂原因%改進措施
가열로냉각수관%단렬원인%개진조시
Heating furnace cooling water pipe%Breaking reason%Improvement measures
在分析了加热炉冷却水管断裂原因的基础上,通过加热炉冷却水管中水质和升降温速度的控制,掏钢方式的改变,基墙和滑轨与水管结构的改进,有效地防止了冷却水管严重变形和断裂事故的发生,提高了生产率,延长了冷却水管的使用寿命,节约了成本,提升了效益。
在分析瞭加熱爐冷卻水管斷裂原因的基礎上,通過加熱爐冷卻水管中水質和升降溫速度的控製,掏鋼方式的改變,基牆和滑軌與水管結構的改進,有效地防止瞭冷卻水管嚴重變形和斷裂事故的髮生,提高瞭生產率,延長瞭冷卻水管的使用壽命,節約瞭成本,提升瞭效益。
재분석료가열로냉각수관단렬원인적기출상,통과가열로냉각수관중수질화승강온속도적공제,도강방식적개변,기장화활궤여수관결구적개진,유효지방지료냉각수관엄중변형화단렬사고적발생,제고료생산솔,연장료냉각수관적사용수명,절약료성본,제승료효익。
Based on analysis of the breaking cause of cooling water pipe of heating furnace , through such actions as controlling the quality of water in the cooling water pipe of heating furnace and tempera -ture up& down speed , changing the way of drawing billet , improving the structure of foundation wall , slide rail and water pipe , serious cooling water pipe deformation and breaking accidents are effectively prevented , productivity is improved , the service life of the cooling water pipe is prolonged , the cost is saved and the benefit is increased .