中华眼外伤职业眼病杂志
中華眼外傷職業眼病雜誌
중화안외상직업안병잡지
CHINESE JOURNAL OF OCULAR TRAUMA AND OCCUPATIONAL EYE DISEASE
2015年
1期
51-52
,共2页
尹娟娟%唐文建%杨潇远%袁军%陈鹏
尹娟娟%唐文建%楊瀟遠%袁軍%陳鵬
윤연연%당문건%양소원%원군%진붕
减压阀,Ahmed%青光眼,开角型%内皮细胞,角膜
減壓閥,Ahmed%青光眼,開角型%內皮細胞,角膜
감압벌,Ahmed%청광안,개각형%내피세포,각막
Valve,glaucoma,Ahmed%Glaucoma,open-angle%Endothelial cell,corneal
目的 探讨Ahmed青光眼减压阀植入术对角膜内皮细胞的影响.方法 对开角型青光眼40例(42眼)行Ahmed减压阀植入术,术后随访观察1、3、6、12个月,手术前后进行角膜内皮细胞密度和细胞形态学的检测.结果 术前平均角膜内皮细胞密度(2586.84±386.30)个/mm2,术后1、3、6、12个月分别为(2545.90±396.74)个/mm2,(2548.75 ±410.36)个/mm2,(2560.20±379.15)个/mm2和(2498.20±402.23)个/mm2,彼此间差异均无统计学意义.细胞形态、平均细胞面积、最小细胞面积、最大细胞面积、六角形细胞百分数、细胞面积标准差、细胞面积变异系数术前术后差异均无统计学意义.结论 一般情况下,Ahmed减压阀植入术不会引起角膜内皮细胞丢失或其它不良影响.
目的 探討Ahmed青光眼減壓閥植入術對角膜內皮細胞的影響.方法 對開角型青光眼40例(42眼)行Ahmed減壓閥植入術,術後隨訪觀察1、3、6、12箇月,手術前後進行角膜內皮細胞密度和細胞形態學的檢測.結果 術前平均角膜內皮細胞密度(2586.84±386.30)箇/mm2,術後1、3、6、12箇月分彆為(2545.90±396.74)箇/mm2,(2548.75 ±410.36)箇/mm2,(2560.20±379.15)箇/mm2和(2498.20±402.23)箇/mm2,彼此間差異均無統計學意義.細胞形態、平均細胞麵積、最小細胞麵積、最大細胞麵積、六角形細胞百分數、細胞麵積標準差、細胞麵積變異繫數術前術後差異均無統計學意義.結論 一般情況下,Ahmed減壓閥植入術不會引起角膜內皮細胞丟失或其它不良影響.
목적 탐토Ahmed청광안감압벌식입술대각막내피세포적영향.방법 대개각형청광안40례(42안)행Ahmed감압벌식입술,술후수방관찰1、3、6、12개월,수술전후진행각막내피세포밀도화세포형태학적검측.결과 술전평균각막내피세포밀도(2586.84±386.30)개/mm2,술후1、3、6、12개월분별위(2545.90±396.74)개/mm2,(2548.75 ±410.36)개/mm2,(2560.20±379.15)개/mm2화(2498.20±402.23)개/mm2,피차간차이균무통계학의의.세포형태、평균세포면적、최소세포면적、최대세포면적、륙각형세포백분수、세포면적표준차、세포면적변이계수술전술후차이균무통계학의의.결론 일반정황하,Ahmed감압벌식입술불회인기각막내피세포주실혹기타불량영향.
Objective To observe the changes of corneal endothelial cell after Ahmed glaucoma valve implantation.Methods Forty-two eyes of 40 patients of primary open-angle glaucoma had accepted cellular morphology and corneal endothelial cell density examination with non-contact corneal endothelial microscope before and after Ahmed glaucoma valve implantation.The follow-up time was 1,3,6,and 12month after surgery.Results The mean endothelial cell density was (2586.84 ±386.30) cells/mm2 before surgery,and 1,3,6,and 12month after surgery,the mean endothelial cell density was (2545.90 ±396.74) cells/mm2,(2548.75 ±410.36) cells/mm2,(2560.20 ± 379.15) cells/mm2,and (2498.20 ±402.23) cells/mm2 respectively.The differences was not statistically significant between before and after surgery on cellular morphology,the mean cellular area,the minimum and the maximum cellular area,the percentage of hexagonal cell,the standard deviation and coefficient variation of cellular area respectively (P > 0.05).Conclusion Under usual condition,Ahmed glaucoma valve implanting has no harmful effect on corneal endothelial cell of patients with primary open-angle glaucoma.