采用新研制的上旋流厌氧反应器/两级好氧组合工艺处理PTA废水,调试运行效果表明,当原水CODCr浓度在8000~14,000mg/L时,处理后出水CODCr在80~100mg/L。调试期间,上旋流厌氧反应器的处理效率可稳定达到80%以上。
採用新研製的上鏇流厭氧反應器/兩級好氧組閤工藝處理PTA廢水,調試運行效果錶明,噹原水CODCr濃度在8000~14,000mg/L時,處理後齣水CODCr在80~100mg/L。調試期間,上鏇流厭氧反應器的處理效率可穩定達到80%以上。
채용신연제적상선류염양반응기/량급호양조합공예처리PTA폐수,조시운행효과표명,당원수CODCr농도재8000~14,000mg/L시,처리후출수CODCr재80~100mg/L。조시기간,상선류염양반응기적처리효솔가은정체도80%이상。
PTA wastewaters are treated by the combined technology of up-revolving lfow anaerobic reactor /two-grade aerobe which are newly adopted. The debugging operation result shows that when the original water CODCr concentration is at 8000~14,000mg/L, water-out CODCr is at 80~100mg/L after treatment. The treatment efifciency of up-revolving lfow anaerobic reactor could be stabilized at over 80% during the debugging period.