化肥设计
化肥設計
화비설계
CHEMICAL FERTILIZER DESIGN
2015年
2期
51-52
,共2页
高温热水泵%振动%汽蚀%打液量%灰水加压泵
高溫熱水泵%振動%汽蝕%打液量%灰水加壓泵
고온열수빙%진동%기식%타액량%회수가압빙
HT hot water pump%vibration%cavitation%capacity%gray water booster pump
针对新能凤凰(滕州)能源有限公司气化工段高温热水泵因振动过大造成多次停车事故、严重制约正常生产的问题,提出了从泵自身设计、管道设计、工艺运行三方面分别查找原因,采取了对管道更改设计、增加灰水加压泵、优化操作参数等措施,结果表明:高温热水泵运行稳定。
針對新能鳳凰(滕州)能源有限公司氣化工段高溫熱水泵因振動過大造成多次停車事故、嚴重製約正常生產的問題,提齣瞭從泵自身設計、管道設計、工藝運行三方麵分彆查找原因,採取瞭對管道更改設計、增加灰水加壓泵、優化操作參數等措施,結果錶明:高溫熱水泵運行穩定。
침대신능봉황(등주)능원유한공사기화공단고온열수빙인진동과대조성다차정차사고、엄중제약정상생산적문제,제출료종빙자신설계、관도설계、공예운행삼방면분별사조원인,채취료대관도경개설계、증가회수가압빙、우화조작삼수등조시,결과표명:고온열수빙운행은정。
Due to the excessive vibration of the high temperature hot water pump in the gasification section of Xinneng Phoenix ( Tengzhou) Energy Co. , Ltd, several emergency shutdowns occurred which seriously restricted the normal production. The author proposes to troubleshoot the issue respec-tively from the aspects of pump design, piping design and process operation and to take measures as change of piping design, erection of gray water booster pump and optimization of operation parameters. The result shows that the high temperature hot water pump runs steadily.