目的:探讨128排螺旋 CT 对胆道引流术后 T 管窦道观察的准确性。方法前瞻性搜集我院2011年5~12月我科行胆道手术后 T 管引流病人共120例,常规术后14 d 行螺旋 CT 检查,观察窦道是否形成。在进行 T 管造影同时通过 T 管旁另插小管进行窦道造影,观察窦道形成情况。以窦道造影无造影剂外漏为诊断窦道形成完整的金标准,观察螺旋 CT 对胆道引流术后 T 管窦道观察的准确性。结果120例病人中,CT 判断窦道形成者有90例,窦道未形成者占30例,经过窦道造影,90例 CT 证实窦道完整的病例窦道均完整,另30例窦道不完整者中,经过窦道造影,有28例发现窦道不完整,有造影剂自 T 管周围漏出,有2例窦道造影显示无造影剂漏出。CT 检查窦道完整性的灵敏度达到97.83%(90/92);特异性达100%(28/28);阳性预测值为100%(90/90);阴性预测值为93.33%(28/30)。结论螺旋CT 可以观察 T 管窦道形成情况,为拔除 T 管前检查窦道的形成提供影像学依据。
目的:探討128排螺鏇 CT 對膽道引流術後 T 管竇道觀察的準確性。方法前瞻性搜集我院2011年5~12月我科行膽道手術後 T 管引流病人共120例,常規術後14 d 行螺鏇 CT 檢查,觀察竇道是否形成。在進行 T 管造影同時通過 T 管徬另插小管進行竇道造影,觀察竇道形成情況。以竇道造影無造影劑外漏為診斷竇道形成完整的金標準,觀察螺鏇 CT 對膽道引流術後 T 管竇道觀察的準確性。結果120例病人中,CT 判斷竇道形成者有90例,竇道未形成者佔30例,經過竇道造影,90例 CT 證實竇道完整的病例竇道均完整,另30例竇道不完整者中,經過竇道造影,有28例髮現竇道不完整,有造影劑自 T 管週圍漏齣,有2例竇道造影顯示無造影劑漏齣。CT 檢查竇道完整性的靈敏度達到97.83%(90/92);特異性達100%(28/28);暘性預測值為100%(90/90);陰性預測值為93.33%(28/30)。結論螺鏇CT 可以觀察 T 管竇道形成情況,為拔除 T 管前檢查竇道的形成提供影像學依據。
목적:탐토128배라선 CT 대담도인류술후 T 관두도관찰적준학성。방법전첨성수집아원2011년5~12월아과행담도수술후 T 관인류병인공120례,상규술후14 d 행라선 CT 검사,관찰두도시부형성。재진행 T 관조영동시통과 T 관방령삽소관진행두도조영,관찰두도형성정황。이두도조영무조영제외루위진단두도형성완정적금표준,관찰라선 CT 대담도인류술후 T 관두도관찰적준학성。결과120례병인중,CT 판단두도형성자유90례,두도미형성자점30례,경과두도조영,90례 CT 증실두도완정적병례두도균완정,령30례두도불완정자중,경과두도조영,유28례발현두도불완정,유조영제자 T 관주위루출,유2례두도조영현시무조영제루출。CT 검사두도완정성적령민도체도97.83%(90/92);특이성체100%(28/28);양성예측치위100%(90/90);음성예측치위93.33%(28/30)。결론라선CT 가이관찰 T 관두도형성정황,위발제 T 관전검사두도적형성제공영상학의거。
Objective To evaluate the accuracy of 128-row helical CT in scanning and diagnosing the for-mation of T tube sinus tract after biliary drainage. Methods The materials of 120 patients who underwent the T tube drainage after the biliary tract operation from May 201 1 to December 201 1 in our hospital were pro-spectively collected.The spiral CT scanning was performed 14 days after the operation to observe whether the sinus tract was formed.Sinus tract radiography was performed to observe the formation of the sinus tract through a small tube inserted near the T-tube when T-tube radiography was carried out.The diagnosed cri-teria was whether the contrast media extravasation existed for judging the accuracy of CT in diagnosing the T-tube sinus tract formation. Results In 120 patients,after the judgment by CT,90 cases had sinus tracts for-mation,while 30 cases had unformed sinus tracts.The complete sinus tracts of the 90 cases which were con-firmed by CT were all complete proven by sinus tract angiography,while in another 30 cases found to be in-complete by CT,28 cases of them were found by the sinus tract angiography to be incomplete with the leakage of contrast agents around the T tube,and the sinus tract angiography of the other 2 cases showed no contrast a-gent leaking.The sensitivity of CT in examining the integrity of the sinus tract reached up to 97.83% (90/92);the specificity reached up to 100% (28/28);the positive predictive value was 100% (90/90);the negative pre-dictive value was 93.33% (28/30). Conclusion The spiral CT can be used to observe the formation of T tube sinus tract,which provides an imaging evidence for examining the formation of sinus tract before the removal of T tube.