为了提高SMA同轴微带连接器的电性能指标,提出一种新设计的SMA同轴微带连接器。该连接器采用2个绝缘支撑限位固定内导体和外导体的相对位置。连接器的尾部采用外导体零件进行压接装配,保证了连接器的机械可靠性;外导体和绝缘支撑没有开孔灌注环氧树脂胶,从根本上规避了连接器的电磁泄漏隐患;并通过仿真优化,整个连接器具有较小的电压驻波比以及较低的插入损耗。采用共面补偿测试方法,所设计的连接器在工作频率范围内,测试电压驻波比VSWR<1.13,插入损耗<0.15 dB,电磁泄漏<-90 dB,较现有的SMA型同轴微带连接器的性能指标都有明显改善。
為瞭提高SMA同軸微帶連接器的電性能指標,提齣一種新設計的SMA同軸微帶連接器。該連接器採用2箇絕緣支撐限位固定內導體和外導體的相對位置。連接器的尾部採用外導體零件進行壓接裝配,保證瞭連接器的機械可靠性;外導體和絕緣支撐沒有開孔灌註環氧樹脂膠,從根本上規避瞭連接器的電磁洩漏隱患;併通過倣真優化,整箇連接器具有較小的電壓駐波比以及較低的插入損耗。採用共麵補償測試方法,所設計的連接器在工作頻率範圍內,測試電壓駐波比VSWR<1.13,插入損耗<0.15 dB,電磁洩漏<-90 dB,較現有的SMA型同軸微帶連接器的性能指標都有明顯改善。
위료제고SMA동축미대련접기적전성능지표,제출일충신설계적SMA동축미대련접기。해련접기채용2개절연지탱한위고정내도체화외도체적상대위치。련접기적미부채용외도체령건진행압접장배,보증료련접기적궤계가고성;외도체화절연지탱몰유개공관주배양수지효,종근본상규피료련접기적전자설루은환;병통과방진우화,정개련접기구유교소적전압주파비이급교저적삽입손모。채용공면보상측시방법,소설계적련접기재공작빈솔범위내,측시전압주파비VSWR<1.13,삽입손모<0.15 dB,전자설루<-90 dB,교현유적SMA형동축미대련접기적성능지표도유명현개선。
Presents a new design of SMA coaxial micro-strip connector in order to improve the SMA coaxial micro-strip connector electric performance index. Two insulated mediums are adopted to fix the relative location of the inner conductor and outer conductor of the proposed connector. A part is pressed into the end of the proposed connector as a part of the out conductor so as to ensure the dependability of the designed connector. The structure of no holes in the outer conductor and the insulated mediums is adopted to avoid the problem of electromagnetic leakage. The proposed connector has good performance of low VSWR and low inserting loss by optimization design. By adopting the improved measurement method of coplanar-offset, the proposed SMA-type coaxial micro-strip connector has good performance, VSWR<1.13, inserting loss<0.15 dB, electromagnetic leakage<-90 dB, which are all better than the performance of current connector.