烟草科技
煙草科技
연초과기
TOBACCO SCIENCE & TECHNOLOGY
2015年
4期
90-92
,共3页
垂直倾斜%切片机%烟包%定位%切片厚度%挡料板
垂直傾斜%切片機%煙包%定位%切片厚度%擋料闆
수직경사%절편궤%연포%정위%절편후도%당료판
Vertical inclination%Slicer%Tobacco bale%Positioning%Slicing thickness%Baffle plate
为解决垂直倾斜切片机烟包分切后因切片厚度不均造成电子秤上物料中断等问题,基于平行四边形双摇杆机构的摆动原理对切片厚度控制系统进行了优化设计。料板背面增设辅助定位气缸,为传动机构提供动力并协助原定位气缸快速定位;通过调节辅助定位气缸活塞杆上的伸缩螺栓,可调整片烟的分切厚度;增加了延时控制功能,烟包定位由挡料板和接近开关共同完成,使挡料板起到阻挡作用。结果表明,通过改进烟包定位控制方法,有效解决了挡料板定位过程中产生晃动和烟包到位检测的不确定性问题,烟包分切厚度均匀稳定,松片回潮机供料中断次数由改进前的15次/月降低为2次/月,提高了松片回潮机的来料稳定性。
為解決垂直傾斜切片機煙包分切後因切片厚度不均造成電子秤上物料中斷等問題,基于平行四邊形雙搖桿機構的襬動原理對切片厚度控製繫統進行瞭優化設計。料闆揹麵增設輔助定位氣缸,為傳動機構提供動力併協助原定位氣缸快速定位;通過調節輔助定位氣缸活塞桿上的伸縮螺栓,可調整片煙的分切厚度;增加瞭延時控製功能,煙包定位由擋料闆和接近開關共同完成,使擋料闆起到阻擋作用。結果錶明,通過改進煙包定位控製方法,有效解決瞭擋料闆定位過程中產生晃動和煙包到位檢測的不確定性問題,煙包分切厚度均勻穩定,鬆片迴潮機供料中斷次數由改進前的15次/月降低為2次/月,提高瞭鬆片迴潮機的來料穩定性。
위해결수직경사절편궤연포분절후인절편후도불균조성전자칭상물료중단등문제,기우평행사변형쌍요간궤구적파동원리대절편후도공제계통진행료우화설계。료판배면증설보조정위기항,위전동궤구제공동력병협조원정위기항쾌속정위;통과조절보조정위기항활새간상적신축라전,가조정편연적분절후도;증가료연시공제공능,연포정위유당료판화접근개관공동완성,사당료판기도조당작용。결과표명,통과개진연포정위공제방법,유효해결료당료판정위과정중산생황동화연포도위검측적불학정성문제,연포분절후도균균은정,송편회조궤공료중단차수유개진전적15차/월강저위2차/월,제고료송편회조궤적래료은정성。
As a solution to the interruption tobacco supply to the electronic belt weigher, caused by uneven slicing, the control system for slicing thickness in the vertical inclination slicer was redesigned based on a parallelogramic double-arm mechanism. An assisted positioning cylinder was installed on the back of the baffle plate to provide power for transmission mechanism and assist the existing positioning cylinder. The slicing thickness could be adjusted by regulating the adjustable bolt on the piston rod of the assisted positioning cylinder. A time delay control was added, the baffle plate worked together with an approach switch to ensure reliable bale positioning. The results showed that by improving the control method for tobacco bale positioning, the baffle plate swaying occurred in the process of positioning and the uncertainty in tobacco bale position detection were effectively solved, the tobacco block was evenly sliced, and the interrupted tobacco supply to conditioners reduced from 15 to 2 times/month.