本文通过分析泉州山美水电站3号机组上导轴承旋转油槽盖板在运行中发生磨损毁坏原因,提出了对上导轴承旋转油槽盖板进行结构改造的技术措施,取得了理想效果,可为类似结构机组的改造提供一个可借鉴的经验。
本文通過分析泉州山美水電站3號機組上導軸承鏇轉油槽蓋闆在運行中髮生磨損燬壞原因,提齣瞭對上導軸承鏇轉油槽蓋闆進行結構改造的技術措施,取得瞭理想效果,可為類似結構機組的改造提供一箇可藉鑒的經驗。
본문통과분석천주산미수전참3호궤조상도축승선전유조개판재운행중발생마손훼배원인,제출료대상도축승선전유조개판진행결구개조적기술조시,취득료이상효과,가위유사결구궤조적개조제공일개가차감적경험。
In the paper,reasons for Shanmei Hydropower Station No.3 unit bearing swivel upper oil drain pan cover plate abrasion damage during operation are analyzed,technical measures of structure transformation in upper guidance bearing swivel oil drain pan cover plate are proposed with ideal effect.It can provide experience for transforming similar structure units as reference.