江苏油田进入高含水开发阶段后,油田地面集输系统的运行效率普遍下降,系统能耗升高,因此建立集输系统能耗分析模型并对其能耗分布和能损分布进行研究是很必要的。针对江苏油田瓦6接转站集输系统利用热力学第一定律和第二定律分别对其能耗现状进行分析,发现加热炉总热负荷主要分布在650~900 kW之间,且随着季节有一定的变化规律,夏季相对较低,冬季相对较高,加热炉月日平均效率夏季一般较高,为75%~78%,冬季较低些,为55%~60%;加热炉火用效率偏低,经分析主要是由于供给燃料量过高、加热炉出口水温过高等原因造成的。并且对影响能耗的因素进行分析,发现减小燃油量或在较高负荷下运行可以提高加热炉效率。
江囌油田進入高含水開髮階段後,油田地麵集輸繫統的運行效率普遍下降,繫統能耗升高,因此建立集輸繫統能耗分析模型併對其能耗分佈和能損分佈進行研究是很必要的。針對江囌油田瓦6接轉站集輸繫統利用熱力學第一定律和第二定律分彆對其能耗現狀進行分析,髮現加熱爐總熱負荷主要分佈在650~900 kW之間,且隨著季節有一定的變化規律,夏季相對較低,鼕季相對較高,加熱爐月日平均效率夏季一般較高,為75%~78%,鼕季較低些,為55%~60%;加熱爐火用效率偏低,經分析主要是由于供給燃料量過高、加熱爐齣口水溫過高等原因造成的。併且對影響能耗的因素進行分析,髮現減小燃油量或在較高負荷下運行可以提高加熱爐效率。
강소유전진입고함수개발계단후,유전지면집수계통적운행효솔보편하강,계통능모승고,인차건립집수계통능모분석모형병대기능모분포화능손분포진행연구시흔필요적。침대강소유전와6접전참집수계통이용열역학제일정률화제이정률분별대기능모현상진행분석,발현가열로총열부하주요분포재650~900 kW지간,차수착계절유일정적변화규률,하계상대교저,동계상대교고,가열로월일평균효솔하계일반교고,위75%~78%,동계교저사,위55%~60%;가열로화용효솔편저,경분석주요시유우공급연료량과고、가열로출구수온과고등원인조성적。병차대영향능모적인소진행분석,발현감소연유량혹재교고부하하운행가이제고가열로효솔。
After entering the high-water-cut exploitation stage , the operating efficiency of oil & gas gathering and transportation system on the Jiangsu oilfield surface generally decreases and the energy consumption increases . Therefore it is necessary to establish an energy analysis model on the gathering system and study the energy distribu -tion and distribution of energy loss of the system .In this paper , the gathering system of Wa 6 Block Station in Jiang-su oilfield is chosen as research subject , the first and second law of thermodynamics are used for energy analysis .It is found that the total heat load of the heating furnace is mainly distributed within 650 ~900 kW, following a cer-tain degree of variation of the season:the heat load is relatively low in summer and relatively high in winter;the av-erage efficiency of the furnace is generally higher in summer , 75%~78%, and somewhat lower in winter , 55%~60%;the exergy efficiency of the heating furnace is low , and the main reasons are found to be excessive amount of supplied fuel and too high water temperature at furnace outlet .The factors affecting energy consumption are also an-alyzed and it is found that reducing fuel flow or operating under high load can improve the efficiency of furnace .