背景:国外动物实验和临床报道复合微孔多聚糖止血效果佳,无迟发性出血发生,并具有良好的组织相容性,对机体无不良反应。目的:分析应用复合微孔多聚糖止血粉减少全髋人工关节置换后失血的疗效和安全性。方法:选择因单侧股骨颈骨折行全髋关节置换患者98例,其中男39例,女59例,年龄61-77岁,采用随机数字表法均分为2组,试验组在行生物型髋关节假体置换缝合伤口前,将复合微孔多聚糖1g直接喷涂在出血部位,放置引流管;对照组缝合前在出血部位仔细电凝止血,放置引流管。记录两组治疗前后血红蛋白水平、失血量、输血率、引流量、凝血指标及下肢深静脉血栓发生率。结果与结论:试验组总失血量、引流量及输血率明显低于对照组(P <0.01),两组治疗后24 h的D-二聚体、血小板计数、活化部分凝血活酶时间值及国际标准化比值比较差异均无显著性意义;两组各1例发生下肢深静脉血栓,下肢深静脉血栓率比较差异无显著性意义;两组均未发生浅表及深部感染现象。表明复合微孔多聚糖止血粉能明显减少单侧全髋关节置换的出血,并具有安全、高效、便捷的特点。
揹景:國外動物實驗和臨床報道複閤微孔多聚糖止血效果佳,無遲髮性齣血髮生,併具有良好的組織相容性,對機體無不良反應。目的:分析應用複閤微孔多聚糖止血粉減少全髖人工關節置換後失血的療效和安全性。方法:選擇因單側股骨頸骨摺行全髖關節置換患者98例,其中男39例,女59例,年齡61-77歲,採用隨機數字錶法均分為2組,試驗組在行生物型髖關節假體置換縫閤傷口前,將複閤微孔多聚糖1g直接噴塗在齣血部位,放置引流管;對照組縫閤前在齣血部位仔細電凝止血,放置引流管。記錄兩組治療前後血紅蛋白水平、失血量、輸血率、引流量、凝血指標及下肢深靜脈血栓髮生率。結果與結論:試驗組總失血量、引流量及輸血率明顯低于對照組(P <0.01),兩組治療後24 h的D-二聚體、血小闆計數、活化部分凝血活酶時間值及國際標準化比值比較差異均無顯著性意義;兩組各1例髮生下肢深靜脈血栓,下肢深靜脈血栓率比較差異無顯著性意義;兩組均未髮生淺錶及深部感染現象。錶明複閤微孔多聚糖止血粉能明顯減少單側全髖關節置換的齣血,併具有安全、高效、便捷的特點。
배경:국외동물실험화림상보도복합미공다취당지혈효과가,무지발성출혈발생,병구유량호적조직상용성,대궤체무불량반응。목적:분석응용복합미공다취당지혈분감소전관인공관절치환후실혈적료효화안전성。방법:선택인단측고골경골절행전관관절치환환자98례,기중남39례,녀59례,년령61-77세,채용수궤수자표법균분위2조,시험조재행생물형관관절가체치환봉합상구전,장복합미공다취당1g직접분도재출혈부위,방치인류관;대조조봉합전재출혈부위자세전응지혈,방치인류관。기록량조치료전후혈홍단백수평、실혈량、수혈솔、인류량、응혈지표급하지심정맥혈전발생솔。결과여결론:시험조총실혈량、인류량급수혈솔명현저우대조조(P <0.01),량조치료후24 h적D-이취체、혈소판계수、활화부분응혈활매시간치급국제표준화비치비교차이균무현저성의의;량조각1례발생하지심정맥혈전,하지심정맥혈전솔비교차이무현저성의의;량조균미발생천표급심부감염현상。표명복합미공다취당지혈분능명현감소단측전관관절치환적출혈,병구유안전、고효、편첩적특점。
BACKGROUND:In foreign animal experiments and clinical reports, microporous polysaccharide hemospheres are characterized as good hemostatic effect, no delayed bleeding, good biocompatibility, and no adverse reactions in the body. OBJECTIVE:To assess the efficacy and safety of microporous polysaccharide hemospheres on reducing blood loss after unilateral total hip arthroplasty. METHODS:Totaly 98 patients who received unilateral total hip arthroplasty due to femoral neck fractures, 39 males and 59 females, aged 61-77 years, were randomly divided into two groups: test group, treated with 1g microporous polysaccharide hemospheres before suture of wound; control group, treated with electric coagulation hemostasis before suturing. Drainage tubes were placed in the two groups. Hemoglobin, blood loss, alogeneic transfusion rate, drainage volume, coagulation index and incidence of deep venous thrombosis of the lower limbs were compared. RESULTS AND CONCLUSION:The total blood loss, drainage volume, and transfusion rate in the test group were significantly lower than those in the control group (P < 0.01), but there were no differences in D-dimer, platelet count, activated partial thromboplastin time and international normalized ratio between the two groups. One case of each group developed deep venous thrombosis of the lower limbs, and no significant difference was in the incidence of deep venous thrombosis between the two groups. No infection occurred. These findings indicate that microporous polysaccharide hemospheres that are safe, effective and convenient can reduce the visible and hidden blood loss after unilateral total hip arthroplasty.