高程%排液%压降%TGNET
高程%排液%壓降%TGNET
고정%배액%압강%TGNET
elevation%fluid discharge%pressure drop%TGNET
为了明确大牛地气田输气管线内是否存在积液,从管道高程、末端分离器排液和管线压降变化三方面进行论证分析。分析表明:液体易于在西1线和中1线内积存,不易在东1线内积存,但末端分离器在清管后没有排过液,且TGNET模拟的理论压降和实际压降差别不大,即西1线、中1线和东1线目前不存在积液;塔榆管线高程整体呈下坡走势,塔榆末站分离器2014年1月—8月没有排过液,且TGNET模拟的理论压降和实际压降差别不大,即塔榆管线存在积液的可能性很小;大杭管线高程平缓,且末端分离器2014年1月—8月没有排过液,不同输气量下TGNET模拟的理论压降与实际压降差别不大,即大杭管线存在积液的可能性很小。
為瞭明確大牛地氣田輸氣管線內是否存在積液,從管道高程、末耑分離器排液和管線壓降變化三方麵進行論證分析。分析錶明:液體易于在西1線和中1線內積存,不易在東1線內積存,但末耑分離器在清管後沒有排過液,且TGNET模擬的理論壓降和實際壓降差彆不大,即西1線、中1線和東1線目前不存在積液;塔榆管線高程整體呈下坡走勢,塔榆末站分離器2014年1月—8月沒有排過液,且TGNET模擬的理論壓降和實際壓降差彆不大,即塔榆管線存在積液的可能性很小;大杭管線高程平緩,且末耑分離器2014年1月—8月沒有排過液,不同輸氣量下TGNET模擬的理論壓降與實際壓降差彆不大,即大杭管線存在積液的可能性很小。
위료명학대우지기전수기관선내시부존재적액,종관도고정、말단분리기배액화관선압강변화삼방면진행론증분석。분석표명:액체역우재서1선화중1선내적존,불역재동1선내적존,단말단분리기재청관후몰유배과액,차TGNET모의적이론압강화실제압강차별불대,즉서1선、중1선화동1선목전불존재적액;탑유관선고정정체정하파주세,탑유말참분리기2014년1월—8월몰유배과액,차TGNET모의적이론압강화실제압강차별불대,즉탑유관선존재적액적가능성흔소;대항관선고정평완,차말단분리기2014년1월—8월몰유배과액,불동수기량하TGNET모의적이론압강여실제압강차별불대,즉대항관선존재적액적가능성흔소。
Daniudi gas field pipelines were analyzed in terms of piping elevation,fluid discharge of separators and pressure change to figure out whether effusion existed. The results showed that fluid was more likely to exist in west line 1 and midline 1 than east line 1,but separators didn’t discharge after pigging and TGNET simulations showed tiny difference between theoretical pressure drop and actual pressure drop,which means no fluid exists in these pipelines. Tayu pipeline overall showed a downhill trend,and separators didn’t discharge from January to August in 2014 and TGNET simulations showed tiny difference between the-oretical pressure drop and actual pressure drop,which means the possibility that fluid exists in Tayu pipeline is very small.Dahang pipeline showed a flat trend,and separators didn’t discharge from January to August in 2014 and TGNET simulations showed tiny difference between theoretical pressure drop and actual pressure drop under different throughput,which means the possibility that fluid exists in Dahang pipeline is very small.