中华整形外科杂志
中華整形外科雜誌
중화정형외과잡지
CHINESE JOURNAL OF PLASTIC SURGERY
2015年
3期
205-208
,共4页
周佳宇%尚巧利%杨庆华%何乐人%蒋海越
週佳宇%尚巧利%楊慶華%何樂人%蔣海越
주가우%상교리%양경화%하악인%장해월
肋软骨%移植,自体%扩张包膜%生物力学
肋軟骨%移植,自體%擴張包膜%生物力學
륵연골%이식,자체%확장포막%생물역학
Costal cartilage%Transplantation,autologous%Expanded capsule%Biomechanics
目的 探讨扩张器包膜对自体异位移植后兔肋软骨生物力学性能的影响.方法 在10只3月龄新西兰大白兔背部脊柱两侧对称埋置15 ml扩张器各4枚,持续扩张1个月后,取出扩张器,一侧去除扩张器包膜为去包膜组,一侧保留扩张器包膜为带包膜组,同时取右侧第7、8肋软骨,去除肋软骨膜后一分为二,分别放置于背部对称扩张囊腔内,分别于术后4、8周取左右对称部位的肋软骨,进行组织学观察.根据试验机要求制成相应大小标准试件进行生物力学测试,对测试结果进行统计学分析处理.结果 8周后,平均极限抗拉强度:去包膜组为(4.954+2.8) MPa,带包膜组为(2.939+0.842) MPa;平均压缩强度:去包膜组为(58.74±13.77) MPa,带包膜组为(47.61±11.41) MPa,去包膜组的抗拉强度及压缩强度均高于带包膜组,差异均有统计学意义(P<0.05),表明去包膜组肋软骨各项生物力学性能优于带包膜组.结论 去除扩张器包膜对移植后肋软骨生物力学性能的保持优于保留扩张器包膜组.
目的 探討擴張器包膜對自體異位移植後兔肋軟骨生物力學性能的影響.方法 在10隻3月齡新西蘭大白兔揹部脊柱兩側對稱埋置15 ml擴張器各4枚,持續擴張1箇月後,取齣擴張器,一側去除擴張器包膜為去包膜組,一側保留擴張器包膜為帶包膜組,同時取右側第7、8肋軟骨,去除肋軟骨膜後一分為二,分彆放置于揹部對稱擴張囊腔內,分彆于術後4、8週取左右對稱部位的肋軟骨,進行組織學觀察.根據試驗機要求製成相應大小標準試件進行生物力學測試,對測試結果進行統計學分析處理.結果 8週後,平均極限抗拉彊度:去包膜組為(4.954+2.8) MPa,帶包膜組為(2.939+0.842) MPa;平均壓縮彊度:去包膜組為(58.74±13.77) MPa,帶包膜組為(47.61±11.41) MPa,去包膜組的抗拉彊度及壓縮彊度均高于帶包膜組,差異均有統計學意義(P<0.05),錶明去包膜組肋軟骨各項生物力學性能優于帶包膜組.結論 去除擴張器包膜對移植後肋軟骨生物力學性能的保持優于保留擴張器包膜組.
목적 탐토확장기포막대자체이위이식후토륵연골생물역학성능적영향.방법 재10지3월령신서란대백토배부척주량측대칭매치15 ml확장기각4매,지속확장1개월후,취출확장기,일측거제확장기포막위거포막조,일측보류확장기포막위대포막조,동시취우측제7、8륵연골,거제륵연골막후일분위이,분별방치우배부대칭확장낭강내,분별우술후4、8주취좌우대칭부위적륵연골,진행조직학관찰.근거시험궤요구제성상응대소표준시건진행생물역학측시,대측시결과진행통계학분석처리.결과 8주후,평균겁한항랍강도:거포막조위(4.954+2.8) MPa,대포막조위(2.939+0.842) MPa;평균압축강도:거포막조위(58.74±13.77) MPa,대포막조위(47.61±11.41) MPa,거포막조적항랍강도급압축강도균고우대포막조,차이균유통계학의의(P<0.05),표명거포막조륵연골각항생물역학성능우우대포막조.결론 거제확장기포막대이식후륵연골생물역학성능적보지우우보류확장기포막조.
Objective To explore the effect of the expanded capsule on biomechanics of the transplanted autologous costal cartilage.Methods Ten New Zealand white rabbits aged 3 months were involved and four 15 ml tissue expanders were implanted symmetrically on the back of each rabbit.After 1 month,expanded capsules were removed (experimental group) on the left side and were reserved (control group) on the right side.Meanwhile,the 6th and 7th costal cartilage without the perichondrium were taken out and each cartilage was divided into two pieces and put under the expanded capsule symmetrically.The cartilage at the upper sides and lower sides were taken out at 4 weeks and 8 weeks later,respectively.All the cartilages were sculptured for the demand of the machine text.The tension and compression property of the cartilages were assessed by the material testing machine(Instron 5967) and the results were analyzed statistically.Results 8 weeks lateral,the average ultimate tension strength was (4.954 + 2.8) MPa in experimental group and (2.939 + 0.842) MPa in control group.The average compressive strength was (58.74 ± 13.77) MPa in experimental group,and(47.61 ± 11.41) MPa in control group.The biomechanics property of the cartilages in the experimental group is better than the control group,and the differences were statistically significant.Conclusions Removing the expanded capsule is benefical to maintain the biomechanics of autologous costal cartilage.