目的:探索 VasoCT支架显影技术在支架辅助弹簧圈栓塞颅内动脉瘤术中的应用。方法连续纳入2013年12月至2014年11月于武警总医院行支架辅助弹簧圈栓塞颅内动脉瘤的20例患者(23个动脉瘤),术毕均行VasoCT扫描,分别对所得图像行支架重建,在XpertCT模式下以容积成像及最大密度投影两种方式观察所得图像,并按支架显影清晰度将所得图像分为非常清晰、欠清晰、不清晰。结果22个由支架辅助栓塞的动脉瘤中,16个完全栓塞,6个不全栓塞,所有支架完全撑开并释放至预定位置;其中11个动脉瘤支架显影清晰,9个动脉瘤显影欠清晰,2个动脉瘤显影不清晰。结论 VasoCT可用于支架辅助动脉瘤栓塞术的效果评估,能够清晰显示支架精微结构、位置、与血管壁的关系及支架与弹簧圈的关系。支架显影清晰度与填塞弹簧圈直径相关,同时受金属伪影投射方向及填塞弹簧圈致密程度影响。
目的:探索 VasoCT支架顯影技術在支架輔助彈簧圈栓塞顱內動脈瘤術中的應用。方法連續納入2013年12月至2014年11月于武警總醫院行支架輔助彈簧圈栓塞顱內動脈瘤的20例患者(23箇動脈瘤),術畢均行VasoCT掃描,分彆對所得圖像行支架重建,在XpertCT模式下以容積成像及最大密度投影兩種方式觀察所得圖像,併按支架顯影清晰度將所得圖像分為非常清晰、欠清晰、不清晰。結果22箇由支架輔助栓塞的動脈瘤中,16箇完全栓塞,6箇不全栓塞,所有支架完全撐開併釋放至預定位置;其中11箇動脈瘤支架顯影清晰,9箇動脈瘤顯影欠清晰,2箇動脈瘤顯影不清晰。結論 VasoCT可用于支架輔助動脈瘤栓塞術的效果評估,能夠清晰顯示支架精微結構、位置、與血管壁的關繫及支架與彈簧圈的關繫。支架顯影清晰度與填塞彈簧圈直徑相關,同時受金屬偽影投射方嚮及填塞彈簧圈緻密程度影響。
목적:탐색 VasoCT지가현영기술재지가보조탄황권전새로내동맥류술중적응용。방법련속납입2013년12월지2014년11월우무경총의원행지가보조탄황권전새로내동맥류적20례환자(23개동맥류),술필균행VasoCT소묘,분별대소득도상행지가중건,재XpertCT모식하이용적성상급최대밀도투영량충방식관찰소득도상,병안지가현영청석도장소득도상분위비상청석、흠청석、불청석。결과22개유지가보조전새적동맥류중,16개완전전새,6개불전전새,소유지가완전탱개병석방지예정위치;기중11개동맥류지가현영청석,9개동맥류현영흠청석,2개동맥류현영불청석。결론 VasoCT가용우지가보조동맥류전새술적효과평고,능구청석현시지가정미결구、위치、여혈관벽적관계급지가여탄황권적관계。지가현영청석도여전새탄황권직경상관,동시수금속위영투사방향급전새탄황권치밀정도영향。
Objective ToexploretheapplicationofVasoCT,astentimagingtechnique,instent-assisted coilaneurysmembolization.Methods Twentyconsecutivepatientswith23intracranialaneurysmswere treated with stent-assisted aneurysm embolization in the General Hospital of Armed Police Forces from December 2013 to November 2014 were enrolled. The patients performed VasoCT scan immediately after procedure. Then all the available images were used for stent-optimized reconstruction respectively. Under the XpertCT mode,the available images were observed with both volume imaging and maximum intensity projection. The available images were analyzed and they were divided into very clear,less clear,and not clearaccordingtothestentdevelopingclarity.Results Ofthe22aneurysmstreatedwithstent-assisted embolization,16 were occluded completely,6 were occluded partially. All the stents were expanded completely and were released to the expected locations;11 aneurysm stents developed clearly,9 developed less clearly,and 2didnotdevelopclearly.Conclusion VasoCTcanbeusedinthestent-assistedaneurysmembolization.It can clearly reveal the microscopic structure of the stents,location,relationship with the artery wall,and relationship between stents and coils. The clarity of stent development is associated with the diameters of the packed coils,and the stents are also affected by the metal artifacts projecting direction and the dense degree of the packing coils.