目的:研究2507双相不锈钢在循环冷却水模拟溶液(添加微生物SRB+IOB)中的腐蚀特征,确定其腐蚀机理。方法模拟某炼油厂循环冷却水溶液,采用SEM,EDS和电化学测试等手段分析2507双相不锈钢在SRB+IOB循环冷却水中浸泡不同时间后的腐蚀产物形貌及其电化学腐蚀情况。结果2507双相不锈钢的腐蚀速率很低,属于轻度腐蚀;在循环冷却水模拟溶液中的阳极极化曲线具有明显的钝化区,且钝化膜具有良好的自修复能力;腐蚀倾向随时间增加先增大后减小,腐蚀速率随时间增加先减小后增大。结论 SRB和IOB及其代谢活动与Cl-协同作用是点蚀的主要原因;2507双相不锈钢具有良好的钝化性和耐微生物腐蚀性能。
目的:研究2507雙相不鏽鋼在循環冷卻水模擬溶液(添加微生物SRB+IOB)中的腐蝕特徵,確定其腐蝕機理。方法模擬某煉油廠循環冷卻水溶液,採用SEM,EDS和電化學測試等手段分析2507雙相不鏽鋼在SRB+IOB循環冷卻水中浸泡不同時間後的腐蝕產物形貌及其電化學腐蝕情況。結果2507雙相不鏽鋼的腐蝕速率很低,屬于輕度腐蝕;在循環冷卻水模擬溶液中的暘極極化麯線具有明顯的鈍化區,且鈍化膜具有良好的自脩複能力;腐蝕傾嚮隨時間增加先增大後減小,腐蝕速率隨時間增加先減小後增大。結論 SRB和IOB及其代謝活動與Cl-協同作用是點蝕的主要原因;2507雙相不鏽鋼具有良好的鈍化性和耐微生物腐蝕性能。
목적:연구2507쌍상불수강재순배냉각수모의용액(첨가미생물SRB+IOB)중적부식특정,학정기부식궤리。방법모의모련유엄순배냉각수용액,채용SEM,EDS화전화학측시등수단분석2507쌍상불수강재SRB+IOB순배냉각수중침포불동시간후적부식산물형모급기전화학부식정황。결과2507쌍상불수강적부식속솔흔저,속우경도부식;재순배냉각수모의용액중적양겁겁화곡선구유명현적둔화구,차둔화막구유량호적자수복능력;부식경향수시간증가선증대후감소,부식속솔수시간증가선감소후증대。결론 SRB화IOB급기대사활동여Cl-협동작용시점식적주요원인;2507쌍상불수강구유량호적둔화성화내미생물부식성능。
ABSTRACT:Objective To study the corrosion characteristics and determine the corrosion mechanism of 2507 duplex stainless steel in circulating cooling water simulated solution containing SRB+IOB. Methods The circulating cooling water in a refinery was simulated, and the morphology of corrosion products and the corrosion mechanism of electrochemical of 2507 duplex stainless steel in circulating cooling water simulated solution containing SRB+IOB were analyzed by SEM, EDS and electrochemical impedance spectroscopy ( EIS) and polarization curves after soaking for different days. Results The corrosion rate of 2507 duplex stainless steel was very low, belonging to mild corrosion. Anodic polarization curves of 2507 duplex stainless steel in circulating cooling wa-ter simulated solution showed significant passivation regions and the passivation film had a good self-healing ability. With increasing corrosion time, the corrosion tendency first increased and then decreased while the corrosion rate first decreased and then in-creased. Conclusion The main cause for the pitting corrosion was the synergic effect of the surface adsorbed SRB and IOB as well as their metabolic activities with Cl-. 2507 duplex stainless steel had a good passivation performance and resistance to microbiologi-cal corrosion.