屏蔽是机房防止闪电电磁脉冲(LEMP)损害的重要措施,而在实际工程中在选择屏蔽材料及设置尺寸时往往缺少依据。文章基于闪电双指数函数模型,利用 MATLAB 软件分析闪电的频谱分布,结合屏蔽措施对LEMP 的防护效果进行研究,确定计算机机房的屏蔽材料应为金属网格,屏蔽网格尺寸应和雷电流幅值相关。并借助雷电监测系统,对近5年来山东省各地闪电数据和雷电流幅值进行统计、分析并针对不同落雷情况,实际计算出计算机机房屏蔽层内外可能出现的磁场强度,借鉴人工引雷试验数据对屏蔽的有效性进行了验证,给出山东省各地机房屏蔽层尺寸的参考值,山东省内机房的屏蔽尺寸应在0.16~0.22 m 之间。
屏蔽是機房防止閃電電磁脈遲(LEMP)損害的重要措施,而在實際工程中在選擇屏蔽材料及設置呎吋時往往缺少依據。文章基于閃電雙指數函數模型,利用 MATLAB 軟件分析閃電的頻譜分佈,結閤屏蔽措施對LEMP 的防護效果進行研究,確定計算機機房的屏蔽材料應為金屬網格,屏蔽網格呎吋應和雷電流幅值相關。併藉助雷電鑑測繫統,對近5年來山東省各地閃電數據和雷電流幅值進行統計、分析併針對不同落雷情況,實際計算齣計算機機房屏蔽層內外可能齣現的磁場彊度,藉鑒人工引雷試驗數據對屏蔽的有效性進行瞭驗證,給齣山東省各地機房屏蔽層呎吋的參攷值,山東省內機房的屏蔽呎吋應在0.16~0.22 m 之間。
병폐시궤방방지섬전전자맥충(LEMP)손해적중요조시,이재실제공정중재선택병폐재료급설치척촌시왕왕결소의거。문장기우섬전쌍지수함수모형,이용 MATLAB 연건분석섬전적빈보분포,결합병폐조시대LEMP 적방호효과진행연구,학정계산궤궤방적병폐재료응위금속망격,병폐망격척촌응화뇌전류폭치상관。병차조뇌전감측계통,대근5년래산동성각지섬전수거화뇌전류폭치진행통계、분석병침대불동락뢰정황,실제계산출계산궤궤방병폐층내외가능출현적자장강도,차감인공인뢰시험수거대병폐적유효성진행료험증,급출산동성각지궤방병폐층척촌적삼고치,산동성내궤방적병폐척촌응재0.16~0.22 m 지간。
Shielding is one of the important measures for the computer room to prevent lightning electromagnetic pulse (LEMP).But how to choose the shielding materials and its size in actual engineering tends to be lack of basis.The purpose of the paper is determining computer room for a targeted protection from LEMP shielding material and size.The paper analyzes the distribution of lightning frequency spectrum by using double exponential function and MATLAB.Based on the research of shielding measures of LEMP protection,it is determined that the computer room shielding materials shall be the metal grid,and the shielding grid size should be related lightning current amplitude.With the help of the lightning monitoring system of Shandong Province,the paper does a statistical analysis of lightning data in the recent 5 years.According to the different situation of lightning,We calculate the possible strength for magnetic field inside and outside the computer room shielding layer,and the effectiveness of the shielding is verified by learning from the experiment of artificially triggered lightning data.According to the actual lightning current amplitude,the paper gives the reference value of shielding layer size for computer room in Shandong province.Calculation shows that the block size of computer room in Shandong province should be between 0.16 m and 0.22 m.