目的:探讨MSCT齿科扫描计划中CT低剂量扫描临床应用的可行性。方法:管电流分为250 mAs常规剂量组及100 mAs低剂量组、50 mAs低剂量组。45例受检者运用随机数字表法分成3组,每组各15例,分别行MSCT齿科扫描计划的常规剂量和低剂量扫描,对获得的图像由放射诊断副主任医师和主任医师各1名在保证图像能够满足诊断的前提下分别进行质量评价,对意见不一致者两人协商确定。结果:MSCT齿科CT低剂量扫描所得图像质量与常规剂量扫描差异无统计学意义( P>0.05)。与常规剂量组相比,低剂量组患者实际接受的放射线剂量长度乘积( dose length product,DLP)及有效剂量E下降,差异有统计学意义。结论:MSCT齿科CT低剂量扫描,能够保证口腔牙齿解剖结构细节显示,可以减少受检者的辐射损伤,临床具有一定的应用价值。
目的:探討MSCT齒科掃描計劃中CT低劑量掃描臨床應用的可行性。方法:管電流分為250 mAs常規劑量組及100 mAs低劑量組、50 mAs低劑量組。45例受檢者運用隨機數字錶法分成3組,每組各15例,分彆行MSCT齒科掃描計劃的常規劑量和低劑量掃描,對穫得的圖像由放射診斷副主任醫師和主任醫師各1名在保證圖像能夠滿足診斷的前提下分彆進行質量評價,對意見不一緻者兩人協商確定。結果:MSCT齒科CT低劑量掃描所得圖像質量與常規劑量掃描差異無統計學意義( P>0.05)。與常規劑量組相比,低劑量組患者實際接受的放射線劑量長度乘積( dose length product,DLP)及有效劑量E下降,差異有統計學意義。結論:MSCT齒科CT低劑量掃描,能夠保證口腔牙齒解剖結構細節顯示,可以減少受檢者的輻射損傷,臨床具有一定的應用價值。
목적:탐토MSCT치과소묘계화중CT저제량소묘림상응용적가행성。방법:관전류분위250 mAs상규제량조급100 mAs저제량조、50 mAs저제량조。45례수검자운용수궤수자표법분성3조,매조각15례,분별행MSCT치과소묘계화적상규제량화저제량소묘,대획득적도상유방사진단부주임의사화주임의사각1명재보증도상능구만족진단적전제하분별진행질량평개,대의견불일치자량인협상학정。결과:MSCT치과CT저제량소묘소득도상질량여상규제량소묘차이무통계학의의( P>0.05)。여상규제량조상비,저제량조환자실제접수적방사선제량장도승적( dose length product,DLP)급유효제량E하강,차이유통계학의의。결론:MSCT치과CT저제량소묘,능구보증구강아치해부결구세절현시,가이감소수검자적복사손상,림상구유일정적응용개치。
Objective:To assess the feasibility of applying low-dose multi-spiral computed tomography(MSCT) to dental scans.Methods:Forty-five pa-tients undergoing MSCT sans were allocated on random number table basis to three groups(n=15 for each),i.e.,standard unenhanced group(tube cur-rent:250 mAs) ,low-dose groups( tube current:100 mAs,50 mAs,respectively) .The images were viewed separately by two radiologists,and any disagree-ment was settled by discussion.Results:The image quality was not significant between the standard unenhanced group and the two low-dose groups( P>0.05).However,the dose-length product (DLP) and the effect dose were decreased for the patients in the two low-dose groups,which was statistically sig-nificant (P<0.05).Conclusion:Low-dose MSCT can clearly expose the anatomical configuration of the temporal bone and prevent the clients from radia-tion injury,which is of certain clinical implications.