stable operation region%pressure fluctuation%vibration%swing
总结了溪洛渡右岸18F机启动试运行试验。检验了厂家的保证值,划分了18F机在全负荷范围的稳定运行区域,并找出了各运行区域振动的主要频率。试验成果有助于溪洛渡东电机组及电网的安全运行。
總結瞭溪洛渡右岸18F機啟動試運行試驗。檢驗瞭廠傢的保證值,劃分瞭18F機在全負荷範圍的穩定運行區域,併找齣瞭各運行區域振動的主要頻率。試驗成果有助于溪洛渡東電機組及電網的安全運行。
총결료계락도우안18F궤계동시운행시험。검험료엄가적보증치,화분료18F궤재전부하범위적은정운행구역,병조출료각운행구역진동적주요빈솔。시험성과유조우계락도동전궤조급전망적안전운행。
The experimental commissioning of the 18F hydro-turbine unit in right bank of the Xiluodu Hydropower Sta-tion is summarized.In the commissioning, manufacturer guarantee values of the unit are examined.The stable operation region of the unit in the whole load range is determined.Also, main vibration frequencies of each operation region are found.These results could be of great use to the safe operation of the hydro-turbine units and the power grid.