以轩岗电厂660 MW超临界机组给水系统变频改造工程为例,分析了超临界机组给水控制系统的特点,提出了变频给水控制系统设计方案.经过生产现场实践检验,取得了良好的控制效果.
以軒崗電廠660 MW超臨界機組給水繫統變頻改造工程為例,分析瞭超臨界機組給水控製繫統的特點,提齣瞭變頻給水控製繫統設計方案.經過生產現場實踐檢驗,取得瞭良好的控製效果.
이헌강전엄660 MW초림계궤조급수계통변빈개조공정위례,분석료초림계궤조급수공제계통적특점,제출료변빈급수공제계통설계방안.경과생산현장실천검험,취득료량호적공제효과.
Taking 660 MW supercritical unit frequency conversion feedwater system reconstruction project in Xuangang power plant as an example, the characteristics of supercritical units feed water control system are analyzed, and the designing scheme of frequency conversion feed water system is put forward. Through practical test, controlling is achieved effectively.