为了实现对凹凸透镜焦距的精准测量,采用彩色数字全息方法进行理论分析和实验验证,取得了与标称值相差1%的数据结果。结果表明,采用数字全息干涉测量方法是可靠的,可以获得与用透镜标称值重构相同的效果。该研究对数字全息波前的重建有帮助。
為瞭實現對凹凸透鏡焦距的精準測量,採用綵色數字全息方法進行理論分析和實驗驗證,取得瞭與標稱值相差1%的數據結果。結果錶明,採用數字全息榦涉測量方法是可靠的,可以穫得與用透鏡標稱值重構相同的效果。該研究對數字全息波前的重建有幫助。
위료실현대요철투경초거적정준측량,채용채색수자전식방법진행이론분석화실험험증,취득료여표칭치상차1%적수거결과。결과표명,채용수자전식간섭측량방법시가고적,가이획득여용투경표칭치중구상동적효과。해연구대수자전식파전적중건유방조。
In order to measure the focal length of a concave and convex lens accurately , theoretical analysis and experimental verification were carried out based on the color digital holographic method , and the measurement difference relative to the nominal value was 1%.The results indicate the digital holographic interferometry is reliable and the same effect as that of lens nominal value reconstruction can be obtained .The result is helpful for digital holographic wavefront reconstruction .