目前在自适应单相重合闸中缺乏对拍频电流表达式、拍频电流是否一定存在及其幅值范围的研究。单相瞬时性故障消失后,拍频电流不存在或过小,都会影响重合闸判定的可靠性。拍频电流受健全相电压和故障消失后线路中元器件初始状态的影响,采用叠加原理得到完整的拍频电流表达式;通过分析表达式得出最小拍频电流及其出现的条件,分析出拍频电流为零属于小概率事件;拍频电流受故障时刻、故障持续时间、电弧电阻、电源相角差及故障位置等共同影响,使得不同工况下的拍频电流差异明显,若幅值过小,将会影响重合闸判定的可靠性。文中利用正交实验的方法给出某500 kV 输电线路拍频电流幅值大小的范围,证明了在工程实践中可以用拍频电流实现自适应重合闸。
目前在自適應單相重閤閘中缺乏對拍頻電流錶達式、拍頻電流是否一定存在及其幅值範圍的研究。單相瞬時性故障消失後,拍頻電流不存在或過小,都會影響重閤閘判定的可靠性。拍頻電流受健全相電壓和故障消失後線路中元器件初始狀態的影響,採用疊加原理得到完整的拍頻電流錶達式;通過分析錶達式得齣最小拍頻電流及其齣現的條件,分析齣拍頻電流為零屬于小概率事件;拍頻電流受故障時刻、故障持續時間、電弧電阻、電源相角差及故障位置等共同影響,使得不同工況下的拍頻電流差異明顯,若幅值過小,將會影響重閤閘判定的可靠性。文中利用正交實驗的方法給齣某500 kV 輸電線路拍頻電流幅值大小的範圍,證明瞭在工程實踐中可以用拍頻電流實現自適應重閤閘。
목전재자괄응단상중합갑중결핍대박빈전류표체식、박빈전류시부일정존재급기폭치범위적연구。단상순시성고장소실후,박빈전류불존재혹과소,도회영향중합갑판정적가고성。박빈전류수건전상전압화고장소실후선로중원기건초시상태적영향,채용첩가원리득도완정적박빈전류표체식;통과분석표체식득출최소박빈전류급기출현적조건,분석출박빈전류위령속우소개솔사건;박빈전류수고장시각、고장지속시간、전호전조、전원상각차급고장위치등공동영향,사득불동공황하적박빈전류차이명현,약폭치과소,장회영향중합갑판정적가고성。문중이용정교실험적방법급출모500 kV 수전선로박빈전류폭치대소적범위,증명료재공정실천중가이용박빈전류실현자괄응중합갑。
At present,researches on the adaptive reclosure lack an analytic expression for beat frequency current about whether the beat frequency current definitely exists and the range of amplitude of the current in adaptive reclosure.The amplitude may be nonexistent or too small when the single-phase transient fault disappears,which will affect the reliability of reclosing determination.The beat frequency current in the shunt reactor is not only affected by sound phase voltage but also by the initial state of components of transmission line when fault disappears.Based on the superposition principle,the complete expression of beat frequency current is obtained,by an analysis of which the minimum beat frequency current and conditions for its occurrence are obtained.It is concluded that the beat frequency current being zero belongs to small probability event.The current is affected by fault time,arc duration,arc resistance,phase angle difference and fault location that make the amplitude obvious.If the amplitude is too small,it will affect the reliability of the reclosing determination.The paper gives the range of amplitude of the beat frequency current on 500 kV transmission lines using the method of the orthogonal experiment in mathematical statistics,proving the beat frequency current can be applied to engineering. This work is supported by National Natural Science Foundation of China(No.50877062).