中南大学学报(英文版)
中南大學學報(英文版)
중남대학학보(영문판)
JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY(ENGLISH EDITION)
2015年
7期
2841-2848
,共8页
潘利生%魏小林%彭岩%时小宝%刘怀亮
潘利生%魏小林%彭巖%時小寶%劉懷亮
반리생%위소림%팽암%시소보%류부량
sinter layer%convection heat transfer%pressure drop
Convection heat transfer coefficient and air pressure drop in sinter layer are important factors for the design of sinter cooling craft. Due to the lack of necessary data, the two parameters are studied by experimental method. The experimental results show that heat conduction of sinter impacts the measurement of convection heat transfer coefficient. Convection heat transfer increases with the increase of air volumetric flow rate. Sinter layer without small particles (sample I) gives higher convection heat transfer coefficient than that with small particles (sample II). Under the considered conditions, volumetric convection heat transfer coefficient is in the range of 400?1800 W/(m3·°C). Air pressure drop in sinter layer increases with the increase of normal superficial velocity, as well as with the rise of air temperature. Additionally, air pressure drop also depends on sinter particle size distribution. In considered experimental conditions, pressure drop in sinter sample II is 2?3 times that in sinter sample I, which resulted from 17% small scale particles in sinter sample II.