虹吸管道%流量%压降%安装高度%水头差%水气两相流
虹吸管道%流量%壓降%安裝高度%水頭差%水氣兩相流
홍흡관도%류량%압강%안장고도%수두차%수기량상류
siphon%flow%pressure drop%setting height%head difference%gas-liquid two-phase flow
通过系列实验量测了不同安装高度、不同水头差下管径为2 cm 虹吸管的流量及压降大小,观察了虹吸管水气两相流流态下气泡及气团流动现象。结果表明,在管道水头一定时,随安装高度的增大,虹吸管的过流能力逐渐减小。在虹吸管的竖直管段中,压降值随管道水头的增大而增大,随安装高度的增加而减小,且虹吸管下行管的压降值明显大于上行管。在水平管段中,压降随管道水头的增大而增大,随安装高度的增大而减小。当虹吸管内发生气液两相流时,沿程水头损失不能直接用达西公式计算,沿程阻力除了受管道水头影响外,还应与安装高度大小有关,安装高度不同,压降值也不相同。
通過繫列實驗量測瞭不同安裝高度、不同水頭差下管徑為2 cm 虹吸管的流量及壓降大小,觀察瞭虹吸管水氣兩相流流態下氣泡及氣糰流動現象。結果錶明,在管道水頭一定時,隨安裝高度的增大,虹吸管的過流能力逐漸減小。在虹吸管的豎直管段中,壓降值隨管道水頭的增大而增大,隨安裝高度的增加而減小,且虹吸管下行管的壓降值明顯大于上行管。在水平管段中,壓降隨管道水頭的增大而增大,隨安裝高度的增大而減小。噹虹吸管內髮生氣液兩相流時,沿程水頭損失不能直接用達西公式計算,沿程阻力除瞭受管道水頭影響外,還應與安裝高度大小有關,安裝高度不同,壓降值也不相同。
통과계렬실험량측료불동안장고도、불동수두차하관경위2 cm 홍흡관적류량급압강대소,관찰료홍흡관수기량상류류태하기포급기단류동현상。결과표명,재관도수두일정시,수안장고도적증대,홍흡관적과류능력축점감소。재홍흡관적수직관단중,압강치수관도수두적증대이증대,수안장고도적증가이감소,차홍흡관하행관적압강치명현대우상행관。재수평관단중,압강수관도수두적증대이증대,수안장고도적증대이감소。당홍흡관내발생기액량상류시,연정수두손실불능직접용체서공식계산,연정조력제료수관도수두영향외,환응여안장고도대소유관,안장고도불동,압강치야불상동。
A series of tests were applied to measure gas-liquid two-phase flow of 2 cm’s diameter of si-phon with different setting heights,difference of different water head and observe bubbles and air mass flow appearance under gass-liquid two-phase flow of siphon.The test results showed that when water head of the pipe was at regular time,with setting height increasing,the overflowing ability of siphon was gradu-ally decreased.In the ascending pipe of siphon,the pressure drop increased with water head of the pipe in-creasing,and decreased with increasing of the setting height.The down pipe’s pressure drop was bigger than the up pipe’s .In the horizontal section,with the water head increasing,the pressure drop was increas-ing;with the increasing of setting height,the pressure drop decreased.When there were air current and liq-uid current in siphon,the streamwise water head loss can not be directly calculated by Darcy formula.The streamwise resistance was not only related to water head of siphon,but also to the setting height.Siphon frictional head loss cannot be directly calculated according to Darcy formula condition,the frictional resist-ance be related to head difference and installation height.The installation height is different,the pressure drop is not the same.