磁共振成像
磁共振成像
자공진성상
CHINESE JOURNAL OF MAGNETIC RESONANCE IMAGING
2015年
8期
603-607
,共5页
王伟%张暹东%李祎%兰岚%戴险峰%张睿%张义彬%黄宁
王偉%張暹東%李祎%蘭嵐%戴險峰%張睿%張義彬%黃寧
왕위%장섬동%리의%란람%대험봉%장예%장의빈%황저
磁共振成像%高强度聚焦超声%平滑肌瘤%子宫肿瘤
磁共振成像%高彊度聚焦超聲%平滑肌瘤%子宮腫瘤
자공진성상%고강도취초초성%평활기류%자궁종류
Magnetic resonance imaging%High-intensity focused ultrasound ablation%Leiomyoma%Uterine neoplasms
目的:通过研究子宫肌瘤动态增强磁共振成像(dynamic contrast-enhanced MRI,DCE-MRI)定量参数与治疗效果的相关性,探讨定量参数对子宫肌瘤高强度聚焦超声(high intensity focused ultrasound,HIFU)治疗效果即时评估的应用价值。材料与方法回顾分析子宫肌瘤HIFU治疗的13个病例,根据治疗后DCE-MRI表现分为完全消融组及不完全消融组。应用Mann-Whitney U秩和检验和Spearman秩相关分析研究定量参数与分组的关联。结果 Ktrans(治疗后)、Ve(治疗后)、Vp(治疗后)与分组呈正相关,相关系数分别为r=0.713、0.757和0.668; Ktrans(变化率)、Ve(变化率)与分组呈负相关,相关系数均为r=-0.802,且相关性更显著。结论 DCE-MRI定量参数对子宫肌瘤HIFU治疗疗效即时评估具有参考价值。
目的:通過研究子宮肌瘤動態增彊磁共振成像(dynamic contrast-enhanced MRI,DCE-MRI)定量參數與治療效果的相關性,探討定量參數對子宮肌瘤高彊度聚焦超聲(high intensity focused ultrasound,HIFU)治療效果即時評估的應用價值。材料與方法迴顧分析子宮肌瘤HIFU治療的13箇病例,根據治療後DCE-MRI錶現分為完全消融組及不完全消融組。應用Mann-Whitney U秩和檢驗和Spearman秩相關分析研究定量參數與分組的關聯。結果 Ktrans(治療後)、Ve(治療後)、Vp(治療後)與分組呈正相關,相關繫數分彆為r=0.713、0.757和0.668; Ktrans(變化率)、Ve(變化率)與分組呈負相關,相關繫數均為r=-0.802,且相關性更顯著。結論 DCE-MRI定量參數對子宮肌瘤HIFU治療療效即時評估具有參攷價值。
목적:통과연구자궁기류동태증강자공진성상(dynamic contrast-enhanced MRI,DCE-MRI)정량삼수여치료효과적상관성,탐토정량삼수대자궁기류고강도취초초성(high intensity focused ultrasound,HIFU)치료효과즉시평고적응용개치。재료여방법회고분석자궁기류HIFU치료적13개병례,근거치료후DCE-MRI표현분위완전소융조급불완전소융조。응용Mann-Whitney U질화검험화Spearman질상관분석연구정량삼수여분조적관련。결과 Ktrans(치료후)、Ve(치료후)、Vp(치료후)여분조정정상관,상관계수분별위r=0.713、0.757화0.668; Ktrans(변화솔)、Ve(변화솔)여분조정부상관,상관계수균위r=-0.802,차상관성경현저。결론 DCE-MRI정량삼수대자궁기류HIFU치료료효즉시평고구유삼고개치。
AbstractObjective:To evaluate the immediate value of dynamic contrast-enhanced MRI(DCE-MRI)quantitative parameters after HIFU treatment of uterine fibroids. Materials and Methods:Thirteen patients with uterine fibroids were scanned with DCE-MRI before and after HIFU ablation. They were grouped into two groups, the complete ablation group and the non-complete ablation group according to appearance of DCE-MRI.Mann-Whitney U test andSpearman's correlations were applied to ifnd the association between quantitative parameters and grouping.Results:Ktrans(after treatment), Ve (after treatment) and Vp (after treatment) were positively correlated with the grouping, and correlation coefifcents were 0.713 , 0.757 and 0.668 respectively. Ktrans(rate of change)and Ve (rate of change) were negatively correlated with the grouping,and correlation coefifcients were both -0.802.Conclusion:DCE-MRI quantitative parameters have reference value in HIFU treatment's immediate effect evaluations for uterine ifbroids.