接触热阻系数影响接触热阻值,进而影响热分析计算的精度。对摄远物镜系统的温度场计算精度的方法进行了研究,首先利用I-DEAS/TMG软件建立二维壳单元有限元模型,仿真计算稳态平衡工况,得到系统各部分的温度水平,然后与MSC.Patran & Nastran的三维体单元结构模型在相同边界条件下的稳态热分析结果进行对比,对比结果表明,接触热阻系数对系统的影响是显著的,在ZTC4与ZTC4之间的接触热阻系数应取160左右,而ZTC4与K9之间的接触热阻系数应为60左右。为光机结构的温度场精度计算提供了保障。
接觸熱阻繫數影響接觸熱阻值,進而影響熱分析計算的精度。對攝遠物鏡繫統的溫度場計算精度的方法進行瞭研究,首先利用I-DEAS/TMG軟件建立二維殼單元有限元模型,倣真計算穩態平衡工況,得到繫統各部分的溫度水平,然後與MSC.Patran & Nastran的三維體單元結構模型在相同邊界條件下的穩態熱分析結果進行對比,對比結果錶明,接觸熱阻繫數對繫統的影響是顯著的,在ZTC4與ZTC4之間的接觸熱阻繫數應取160左右,而ZTC4與K9之間的接觸熱阻繫數應為60左右。為光機結構的溫度場精度計算提供瞭保障。
접촉열조계수영향접촉열조치,진이영향열분석계산적정도。대섭원물경계통적온도장계산정도적방법진행료연구,수선이용I-DEAS/TMG연건건립이유각단원유한원모형,방진계산은태평형공황,득도계통각부분적온도수평,연후여MSC.Patran & Nastran적삼유체단원결구모형재상동변계조건하적은태열분석결과진행대비,대비결과표명,접촉열조계수대계통적영향시현저적,재ZTC4여ZTC4지간적접촉열조계수응취160좌우,이ZTC4여K9지간적접촉열조계수응위60좌우。위광궤결구적온도장정도계산제공료보장。
Since the contact resistance coefficient affect the contact thermal resistance,thereby the accuracy of the ther-mal analysis and calculation is affected. In this paper,the accuracy of the temperature field calculation method for tele-photo lens system were studied. At first,the I-DEAS/TMG software is used to establish a two-dimensional finite ele-ment model of the shell;the steady-state equilibrium conditions is simulated;the temperature level of each part of the system is got. Then the three-dimensional structure models of MSC. Patran & Nastran steady-state thermal analysis unit are compared under the same boundary conditions;the comparison results show that it is significant that the ther-mal contact resistance coefficient impact on the system;the contact thermal resistance coefficient between ZTC4 and ZTC4 should be taken about 160;and the contact resistance and coefficient between ZTC4 and K9 should be about 60 to provide a guarantee for field precision calculation. This important factor should not be overlooked for research on pre-cision instruments for modeling.