目的 应用显微镜镜检、Sysmex UF-500i全自动尿沉渣分析仪和AVE-763尿沉渣智能分析仪三种方法进行尿沉渣检测分析的效果.方法 随机选择100例红细胞、白细胞、上皮细胞和管型均为阳性标本,分别应用显微镜镜检为A组、Sysmex UF-500i全自动尿沉渣分析仪为B组和AVE-763尿沉渣智能分析仪为C组进行尿沉渣检测,并分析这三组方法的检测结果.结果 在红细胞计数(RBC)、白细胞计数(WBC)、上皮细胞计数(EC)和管型计数(CAST)中,A组与B组均无显著性差别,C组与A、B组均有显著性差别;A组与B组的RBC、WBC、EC和CAST相关性系数分别为:r=0.95、r=0.94、r=0.97和r=0.90,A组与C组的RBC、WBC、EC和CAST相关性系数分别为:r=0.72、r=0.67、r=0.71和r=0.54.结论 显微镜镜检和Sysmex UF-500i全自动尿沉渣分析仪准确率及一致性均优于AVE-763尿沉渣智能分析仪,Sysmex UF-500i全自动尿沉渣分析仪检测效率与自动化程度高于显微镜镜检.
目的 應用顯微鏡鏡檢、Sysmex UF-500i全自動尿沉渣分析儀和AVE-763尿沉渣智能分析儀三種方法進行尿沉渣檢測分析的效果.方法 隨機選擇100例紅細胞、白細胞、上皮細胞和管型均為暘性標本,分彆應用顯微鏡鏡檢為A組、Sysmex UF-500i全自動尿沉渣分析儀為B組和AVE-763尿沉渣智能分析儀為C組進行尿沉渣檢測,併分析這三組方法的檢測結果.結果 在紅細胞計數(RBC)、白細胞計數(WBC)、上皮細胞計數(EC)和管型計數(CAST)中,A組與B組均無顯著性差彆,C組與A、B組均有顯著性差彆;A組與B組的RBC、WBC、EC和CAST相關性繫數分彆為:r=0.95、r=0.94、r=0.97和r=0.90,A組與C組的RBC、WBC、EC和CAST相關性繫數分彆為:r=0.72、r=0.67、r=0.71和r=0.54.結論 顯微鏡鏡檢和Sysmex UF-500i全自動尿沉渣分析儀準確率及一緻性均優于AVE-763尿沉渣智能分析儀,Sysmex UF-500i全自動尿沉渣分析儀檢測效率與自動化程度高于顯微鏡鏡檢.
목적 응용현미경경검、Sysmex UF-500i전자동뇨침사분석의화AVE-763뇨침사지능분석의삼충방법진행뇨침사검측분석적효과.방법 수궤선택100례홍세포、백세포、상피세포화관형균위양성표본,분별응용현미경경검위A조、Sysmex UF-500i전자동뇨침사분석의위B조화AVE-763뇨침사지능분석의위C조진행뇨침사검측,병분석저삼조방법적검측결과.결과 재홍세포계수(RBC)、백세포계수(WBC)、상피세포계수(EC)화관형계수(CAST)중,A조여B조균무현저성차별,C조여A、B조균유현저성차별;A조여B조적RBC、WBC、EC화CAST상관성계수분별위:r=0.95、r=0.94、r=0.97화r=0.90,A조여C조적RBC、WBC、EC화CAST상관성계수분별위:r=0.72、r=0.67、r=0.71화r=0.54.결론 현미경경검화Sysmex UF-500i전자동뇨침사분석의준학솔급일치성균우우AVE-763뇨침사지능분석의,Sysmex UF-500i전자동뇨침사분석의검측효솔여자동화정도고우현미경경검.
Objective Applications microscopic examination, Sysmex UF-500i automated urine analyzer and AVE-763 Urine Analyzer intelligent three methods to detect the effect of urine sediment analysis.Methods Randomly selected 100 cases of red blood cells,white blood cells,and tubular epithelial cells were positive specimens for microscopic examination were applied in group A,Sysmex UF-500i automated urine analyzer for group B and AVE-763 Urine Analyzer for intelligent Urine group C were tested and the results of these three groups of analysis and detection methods.Results In the red blood cell count (RBC),white blood cell count (WBC),epithelial cell count (EC) and the tube type counter (CAST),The Group A and The Group B were not significantly different,The Group C were the group A and the group B were significant differences;RBC,WBC,EC and CAST of The A group with the group B correlation coefficients were:r=0.95,r=0.94,r=0.97 andr=0.90,RBC,WBC,EC and CAST of The A group with the group C correlation coefficients were:r=0.72、r=0.67、r=0.71和r=0.54.Conclusions Microscopic examination and Sysmex UF-500i automated urine analyzer accuracy and consistency are better than AVE-763 Urine Analyzer intelligent,automated urine analyzer efficiency and automation to detect UF-500i Sysmex higher than the microscope inspection.