为了解决大化水电厂G型螺杆泵出现烧杆及铜套磨损,进行各种原因分析,以及在检修中进行了修磨处理、密封垫片改造及检修处理工艺改进等,设备改造后运行至今,不仅大大减少了设备的维护量,还有效提高了设备运行的可靠性,保证了机组的安全运行.
為瞭解決大化水電廠G型螺桿泵齣現燒桿及銅套磨損,進行各種原因分析,以及在檢脩中進行瞭脩磨處理、密封墊片改造及檢脩處理工藝改進等,設備改造後運行至今,不僅大大減少瞭設備的維護量,還有效提高瞭設備運行的可靠性,保證瞭機組的安全運行.
위료해결대화수전엄G형라간빙출현소간급동투마손,진행각충원인분석,이급재검수중진행료수마처리、밀봉점편개조급검수처리공예개진등,설비개조후운행지금,불부대대감소료설비적유호량,환유효제고료설비운행적가고성,보증료궤조적안전운행.
The reasons of G-type screw pump rod burnout and copper bush wear are analyzed, and then the counter-measures, like grinding screw rod, replacing sealing gasket and improving maintenance technology etc., are proposed and taken during the maintenance period, so as to reduce the mentioned failures. The equipment upgrading not only reduces the maintenance work, but also improves the operational reliability of the equipment and ensures the safe op-eration of the unit.