针对国内燃煤机组排烟温度普遍偏高问题,提出采用烟气余热回收技术对系统进行改造.通过引入“相对效益”的概念,建立“相对效益”热力计算模型,并以“相对效益”和经济效益作为综合指标,分析了烟气参数、凝结水参数、换热器结构参数对烟气余热回收系统整体水平的影响规律.在保证机组安全运行的前提下,应结合系统防腐、防磨、防积灰特性,通过调整上述参数对烟气余热回收系统进行优化.对某600 MW 机组的实际计算结果表明,系统优化后比优化前的设备质量减少了3.9%,相对效益提高了4.4%.
針對國內燃煤機組排煙溫度普遍偏高問題,提齣採用煙氣餘熱迴收技術對繫統進行改造.通過引入“相對效益”的概唸,建立“相對效益”熱力計算模型,併以“相對效益”和經濟效益作為綜閤指標,分析瞭煙氣參數、凝結水參數、換熱器結構參數對煙氣餘熱迴收繫統整體水平的影響規律.在保證機組安全運行的前提下,應結閤繫統防腐、防磨、防積灰特性,通過調整上述參數對煙氣餘熱迴收繫統進行優化.對某600 MW 機組的實際計算結果錶明,繫統優化後比優化前的設備質量減少瞭3.9%,相對效益提高瞭4.4%.
침대국내연매궤조배연온도보편편고문제,제출채용연기여열회수기술대계통진행개조.통과인입“상대효익”적개념,건립“상대효익”열력계산모형,병이“상대효익”화경제효익작위종합지표,분석료연기삼수、응결수삼수、환열기결구삼수대연기여열회수계통정체수평적영향규률.재보증궤조안전운행적전제하,응결합계통방부、방마、방적회특성,통과조정상술삼수대연기여열회수계통진행우화.대모600 MW 궤조적실제계산결과표명,계통우화후비우화전적설비질량감소료3.9%,상대효익제고료4.4%.
Generally,the exhaust gas temperature in domestic coal-fired units is relatively high.Aiming at solving this problem,the flue gas waste heat recovery technology was proposed to carry out technical trans-formation for the unit.By introducing the concept of"relative efficiency",the"relative efficiency" thermo-dynamic calculation model was established.Moreover,considering the "relative efficiency" and economic benefits as a comprehensive index,the influence of such key factors as flue gas parameters,condensate pa-rameters and heat exchanger's structural parameters on overall performance of the flue gas waste heat re-covery system was investigated.On the premise of ensuring the unit safety operation,the corrosion resist-ance,performances of the system like the wear resistance and ash deposition resistance should be consid-ered to optimize the system by regulating the parameters mentioned above.Taking a 600 MW unit as the example,the calculation results show that,after the optimization,the equipment mass of the system de-creased by 3.9%,the relative efficiency increased by 4.4%.