水动力学研究与进展A辑
水動力學研究與進展A輯
수동역학연구여진전A집
Journal of Hydrodynamics
2015年
4期
391-400
,共10页
颜健%彭佑多%易陈斐%肖蓉
顏健%彭祐多%易陳斐%肖蓉
안건%팽우다%역진비%초용
机架群%风荷载%静力干扰效应%遮挡效应%流线图
機架群%風荷載%靜力榦擾效應%遮擋效應%流線圖
궤가군%풍하재%정력간우효응%차당효응%류선도
frame group%wind load%static interference effect%shielding effect%streamlined diagram
该文基于Fluent 6.3软件平台,选用Realizable k-?湍流模型开展两碟式机架静风载荷干扰效应研究。选取了单机架情况的三种最不利载荷工况,模拟了两机架基本布置形式(串列、并列和斜列)和布置间距对各工况机架风载荷的干扰,给出了各布置下的受扰机架静风载荷干扰因子,分析了干扰因子随布置形式及间距的变化规律,通过流场流线图探讨了机架风载荷干扰的产生原因。研究结果表明,串列布置的下游受扰机架静风载荷干扰因子均小于1.0表现为“遮挡效应”,而上游施扰机架的风载荷趋于单体情况;斜列布置的干扰效应也表现为“遮挡效应”,但较串列干扰弱;并列布置的两机架中间有形成“狭缝效应”,但效果不显著。
該文基于Fluent 6.3軟件平檯,選用Realizable k-?湍流模型開展兩碟式機架靜風載荷榦擾效應研究。選取瞭單機架情況的三種最不利載荷工況,模擬瞭兩機架基本佈置形式(串列、併列和斜列)和佈置間距對各工況機架風載荷的榦擾,給齣瞭各佈置下的受擾機架靜風載荷榦擾因子,分析瞭榦擾因子隨佈置形式及間距的變化規律,通過流場流線圖探討瞭機架風載荷榦擾的產生原因。研究結果錶明,串列佈置的下遊受擾機架靜風載荷榦擾因子均小于1.0錶現為“遮擋效應”,而上遊施擾機架的風載荷趨于單體情況;斜列佈置的榦擾效應也錶現為“遮擋效應”,但較串列榦擾弱;併列佈置的兩機架中間有形成“狹縫效應”,但效果不顯著。
해문기우Fluent 6.3연건평태,선용Realizable k-?단류모형개전량설식궤가정풍재하간우효응연구。선취료단궤가정황적삼충최불리재하공황,모의료량궤가기본포치형식(천렬、병렬화사렬)화포치간거대각공황궤가풍재하적간우,급출료각포치하적수우궤가정풍재하간우인자,분석료간우인자수포치형식급간거적변화규률,통과류장류선도탐토료궤가풍재하간우적산생원인。연구결과표명,천렬포치적하유수우궤가정풍재하간우인자균소우1.0표현위“차당효응”,이상유시우궤가적풍재하추우단체정황;사렬포치적간우효응야표현위“차당효응”,단교천렬간우약;병렬포치적량궤가중간유형성“협봉효응”,단효과불현저。
Based on software Fluent6.3, the effects of two disc frames static wind load interference were investigated in a Realizable k-? turbulence model. Three kinds of the most unfavorable load conditions in single rack situation were selected, then the interference effects of two racks basic layout forms (serial, parallel and inclined columns) and distances were simulated.The static wind load interference factors of each arrangement interfered frames were obtained, then the change rule of interference factors coincided with the arrangement of the layout form and distance were analyzed and the causes of wind load disturbance on frame were explored through the flow field streamline diagram. The results showed that static wind load factor of tandem downstream disturbed frame was below 1.0, which demonstrated a“shielding effect”, whereas the wind load of the upper frame tended to monomer case. Moreover, the interference effects of inclined column layout were also showed a “shielding effect”, but weaker than the serial interference. The interference effects between two parallel frames formed a“slit effect”, but the effects were not significant.