暖通空调
暖通空調
난통공조
Heating Ventilating & Air Conditioning
2015年
9期
80-84,56
,共6页
白鲁建%张毅%杨柳%宋冰
白魯建%張毅%楊柳%宋冰
백로건%장의%양류%송빙
苏北传统民居%室内热环境%实测%室内温度%壁面温度%热舒适
囌北傳統民居%室內熱環境%實測%室內溫度%壁麵溫度%熱舒適
소북전통민거%실내열배경%실측%실내온도%벽면온도%열서괄
traditional dwelling of North Jiangsu%indoor thermal environment%field measurement%indoor temperature%wall temperature%thermal comfort
对苏北沿海地区传统民居及新民居的夏季室内热环境进行了实测对比研究,发现传统民居全天室内温度波动幅度比新民居小,热稳定性更好。通过对二者壁面温度的分析发现,传统民居围护结构具有更好的热稳定性。传统民居室内空气温度纵向有分层,屋顶处空气温度比1.5 m 处高2.4℃。传统民居由于单面开窗,夏季室内通风不畅,全天室内风速不足0.1 m/s,夜间室内风速仅为0.01 m/s。运用 Fanger 提出的 PMV-PPD 修正模型对室内热环境舒适度进行了预测分析,发现传统民居夏季室内舒适度较差,全天室内 PMVe 计算值均在0.85以上。
對囌北沿海地區傳統民居及新民居的夏季室內熱環境進行瞭實測對比研究,髮現傳統民居全天室內溫度波動幅度比新民居小,熱穩定性更好。通過對二者壁麵溫度的分析髮現,傳統民居圍護結構具有更好的熱穩定性。傳統民居室內空氣溫度縱嚮有分層,屋頂處空氣溫度比1.5 m 處高2.4℃。傳統民居由于單麵開窗,夏季室內通風不暢,全天室內風速不足0.1 m/s,夜間室內風速僅為0.01 m/s。運用 Fanger 提齣的 PMV-PPD 脩正模型對室內熱環境舒適度進行瞭預測分析,髮現傳統民居夏季室內舒適度較差,全天室內 PMVe 計算值均在0.85以上。
대소북연해지구전통민거급신민거적하계실내열배경진행료실측대비연구,발현전통민거전천실내온도파동폭도비신민거소,열은정성경호。통과대이자벽면온도적분석발현,전통민거위호결구구유경호적열은정성。전통민거실내공기온도종향유분층,옥정처공기온도비1.5 m 처고2.4℃。전통민거유우단면개창,하계실내통풍불창,전천실내풍속불족0.1 m/s,야간실내풍속부위0.01 m/s。운용 Fanger 제출적 PMV-PPD 수정모형대실내열배경서괄도진행료예측분석,발현전통민거하계실내서괄도교차,전천실내 PMVe 계산치균재0.85이상。
Through contrasting the indoor thermal environment in the traditional dwelling with the new built dwelling in coastal North Jiangsu in summer,finds that the indoor temperature fluctuation of the traditional one is less than that of the new in all day,and the thermal stability is better.Compares the wall temperature in the traditional dwelling with that in the new built dwelling,finds that the thermal stability of the envelope in the traditional dwelling is better.The indoor temperature has the characteristics of vertical stratification in the traditional dwelling.The indoor temperature near the roof is 2.4 ℃ higher than that at 1.5 meters.Only one-side opened window leads to weak ventilation effect in the traditional dwelling.The indoor ventilation velocity is less than 0.1 m/s in all day and it is only 0.01 m/s at night.By using modified PMV-PPD model to predict the thermal comfort,finds that the indoor thermal comfort is worse in the traditional dwelling and the PMVe is above 0.85.