中国医院
中國醫院
중국의원
Chinese Hospitals
2015年
10期
22-25
,共4页
张娜%李少冬%崔怀信%李先池%刘学奎
張娜%李少鼕%崔懷信%李先池%劉學奎
장나%리소동%최부신%리선지%류학규
运行病历%书写质量%实时监控
運行病歷%書寫質量%實時鑑控
운행병력%서사질량%실시감공
medical records%writing quality%real-time monitoring
目的:研究医疗质量实时监控系统是否可以提高运行病历的书写质量.方法:对实时监控前后共4年的运行病历书写质量进行回顾性分析,监控前共抽查960份运行病历,监控后检查24255份运行病历,从运行病历书写的及时性、完整性、内涵质量3个方面进行汇总分析.结果:监控前,运行病历书写的及时性、完整性、内涵质量的达标率分别为79.4%、94.9%、91.8%;监控后,3个指标的达标率分别为85.2%、98.2%、93.6%,病历书写及时性、完整性较监控前具有显著性差异(P<0.001),而病历书写内涵质量并无显著差异(P=0.114);监控后随时间变化,运行病历完整性达标率整体呈上升趋势,运行病历内涵质量达标率有轻度上升,运行病历及时性达标率先下降后上升.结论:医疗质量实时监控系统的应用是提高运行病历书写的及时性、完整性的有效方法,但对提高运行病历书写的内涵质量效果不明显.
目的:研究醫療質量實時鑑控繫統是否可以提高運行病歷的書寫質量.方法:對實時鑑控前後共4年的運行病歷書寫質量進行迴顧性分析,鑑控前共抽查960份運行病歷,鑑控後檢查24255份運行病歷,從運行病歷書寫的及時性、完整性、內涵質量3箇方麵進行彙總分析.結果:鑑控前,運行病歷書寫的及時性、完整性、內涵質量的達標率分彆為79.4%、94.9%、91.8%;鑑控後,3箇指標的達標率分彆為85.2%、98.2%、93.6%,病歷書寫及時性、完整性較鑑控前具有顯著性差異(P<0.001),而病歷書寫內涵質量併無顯著差異(P=0.114);鑑控後隨時間變化,運行病歷完整性達標率整體呈上升趨勢,運行病歷內涵質量達標率有輕度上升,運行病歷及時性達標率先下降後上升.結論:醫療質量實時鑑控繫統的應用是提高運行病歷書寫的及時性、完整性的有效方法,但對提高運行病歷書寫的內涵質量效果不明顯.
목적:연구의료질량실시감공계통시부가이제고운행병력적서사질량.방법:대실시감공전후공4년적운행병역서사질량진행회고성분석,감공전공추사960빈운행병력,감공후검사24255빈운행병력,종운행병역서사적급시성、완정성、내함질량3개방면진행회총분석.결과:감공전,운행병역서사적급시성、완정성、내함질량적체표솔분별위79.4%、94.9%、91.8%;감공후,3개지표적체표솔분별위85.2%、98.2%、93.6%,병역서사급시성、완정성교감공전구유현저성차이(P<0.001),이병역서사내함질량병무현저차이(P=0.114);감공후수시간변화,운행병력완정성체표솔정체정상승추세,운행병력내함질량체표솔유경도상승,운행병력급시성체표솔선하강후상승.결론:의료질량실시감공계통적응용시제고운행병역서사적급시성、완정성적유효방법,단대제고운행병역서사적내함질량효과불명현.
Objectives: To study whether real-time monitoring system of medical quality can improve the writing quality of medical record. Methods: Retrospective analysis are made to compare the writing quality of medical records in four years before and after the real-time monitoring. 960 and 24255 medical records were randomly selected before and after implementing real time monitoring respectively. Timeliness, integrity and connotation of medical records were analyzed. Results: Before the monitoring,the respective up-to-standard rate of timeliness, completeness, connotation of medical record is 79.4%, 94.9% and 91.8%, and after monitoring,the respective up-to-standard rate of these three indicators is 85.2%, 98.2% and 93.6%. The timeliness and integrity of medical record shows a significant difference(P<0.001),but connotation of the medical record writing (P=0.114) has no significant change. After the monitoring, with time passing,the up-to-standard rate of integrity rises as a whole, the rate of connotation rises mildly, and the rate of timeliness rises first and then falls. Conclusions: Medical quality real-time monitoring and control system is an effective method to improve the timeliness and integrity of medical record writing but has no significant influence on connotation of the medical record writing.