伍斯静%丘兴旺%黄世明%李梁军
伍斯靜%丘興旺%黃世明%李樑軍
오사정%구흥왕%황세명%리량군
重量法%铅锑精矿%硫
重量法%鉛銻精礦%硫
중량법%연제정광%류
Weight method%lead antimony concentrate%sulfur
采用碳酸钠-氧化锌混合物半熔,将试样中的硫全部转化成可溶性硫酸盐,然后用硫酸钡重量法测定铅锑精矿中硫含量.用本法测定硫量,方法精密度高,准确度好,结果稳定可靠,硫的测定范围为15.00%~30.00%;方法精密度(RSD值为)为0.314%~0.550%,回收率在99.24%~101.78%之间,完全满足铅锑精矿中硫量的测定要求.
採用碳痠鈉-氧化鋅混閤物半鎔,將試樣中的硫全部轉化成可溶性硫痠鹽,然後用硫痠鋇重量法測定鉛銻精礦中硫含量.用本法測定硫量,方法精密度高,準確度好,結果穩定可靠,硫的測定範圍為15.00%~30.00%;方法精密度(RSD值為)為0.314%~0.550%,迴收率在99.24%~101.78%之間,完全滿足鉛銻精礦中硫量的測定要求.
채용탄산납-양화자혼합물반용,장시양중적류전부전화성가용성류산염,연후용류산패중량법측정연제정광중류함량.용본법측정류량,방법정밀도고,준학도호,결과은정가고,류적측정범위위15.00%~30.00%;방법정밀도(RSD치위)위0.314%~0.550%,회수솔재99.24%~101.78%지간,완전만족연제정광중류량적측정요구.
The sample with sodium carbonate - half of molten zinc oxide mixture, all converted into soluble sulfate sulfur, and then with barium sulfate weight method determination of sulfur content in lead antimony concentrate.Sulfur was measured by this law, the method is of high precision and good accuracy, stable and reliable results, the determination of sulfur range is 15.00%~30.00%;Precision (RSD) value is 0.314%~0.550%, recovery rate was between 99.24%~101.78%, completely meet the requirements of the determination of sulfur content in lead antimony concentrate.