农业工程学报
農業工程學報
농업공정학보
Transactions of the Chinese Society of Agricultural Engineering
2015年
19期
54-60
,共7页
卢金玲%邓佳%徐益荣%冯建军%罗兴锜
盧金玲%鄧佳%徐益榮%馮建軍%囉興锜
로금령%산가%서익영%풍건군%라흥기
离心泵%叶轮%压力%诱导轮%时序位置
離心泵%葉輪%壓力%誘導輪%時序位置
리심빙%협륜%압력%유도륜%시서위치
centrifugal pumps%impellers%pressure%inducer%clocking position
对带有诱导轮的离心泵而言,诱导轮相对叶轮的时序位置非常关键。为探讨时序位置对整台离心泵性能的影响,该文以某单级离心泵为研究对象,采用三维黏性非定常数值方法,对诱导轮相对叶轮的3种不同时序位置下离心泵的内部流动进行了模拟,并分析了其外特性、振动特性、空化特性随时序位置的变化。结果表明:随诱导轮时序位置的变化,离心泵的扬程和效率都是先增大后减小,扬程变化达1.3%,效率变化达1.32%;诱导轮叶片尾部压力面的漩涡逐渐消失。时序效应对叶轮与径向导叶间的动静干涉有影响,从而影响叶轮所受径向力的分布及叶轮内部和径向导叶头部的压力脉动特性;合理的时序位置可以改善离心泵的空化性能。
對帶有誘導輪的離心泵而言,誘導輪相對葉輪的時序位置非常關鍵。為探討時序位置對整檯離心泵性能的影響,該文以某單級離心泵為研究對象,採用三維黏性非定常數值方法,對誘導輪相對葉輪的3種不同時序位置下離心泵的內部流動進行瞭模擬,併分析瞭其外特性、振動特性、空化特性隨時序位置的變化。結果錶明:隨誘導輪時序位置的變化,離心泵的颺程和效率都是先增大後減小,颺程變化達1.3%,效率變化達1.32%;誘導輪葉片尾部壓力麵的漩渦逐漸消失。時序效應對葉輪與徑嚮導葉間的動靜榦涉有影響,從而影響葉輪所受徑嚮力的分佈及葉輪內部和徑嚮導葉頭部的壓力脈動特性;閤理的時序位置可以改善離心泵的空化性能。
대대유유도륜적리심빙이언,유도륜상대협륜적시서위치비상관건。위탐토시서위치대정태리심빙성능적영향,해문이모단급리심빙위연구대상,채용삼유점성비정상수치방법,대유도륜상대협륜적3충불동시서위치하리심빙적내부류동진행료모의,병분석료기외특성、진동특성、공화특성수시서위치적변화。결과표명:수유도륜시서위치적변화,리심빙적양정화효솔도시선증대후감소,양정변화체1.3%,효솔변화체1.32%;유도륜협편미부압력면적선와축점소실。시서효응대협륜여경향도협간적동정간섭유영향,종이영향협륜소수경향력적분포급협륜내부화경향도협두부적압력맥동특성;합리적시서위치가이개선리심빙적공화성능。
Different circumferential positions of stator/stator, rotor/rotor, stator /rotor have different wake vortex, which has different effects on the downstream blade boundary. This phenomenon is called clocking effect. The clocking effect has been widely used in the radial and axial pneumatic machinery, and the aerodynamic performance has been greatly improved. However, clocking effect is rarely used in hydraulic machinery, especially for hydraulic machinery with inducer. For the viscosity of the water is much larger than that of most gases, large trail vortex may occur at the downstream of vanes of hydraulic machinery, even at low flow velocity. When entering the impeller, this kind of vortex may further develop and mix with each other in the impeller. New vortex may be brought out downstream of the impeller, resulting in a greater impact on overall performance. Thus, the clocking effects may play a more important role in hydraulic machinery than pneumatic machinery. In order to study the influence of clocking effect on centrifugal pump, a single-stage centrifugal pump was selected as the study object, and three-dimensional unsteady viscous numerical method was applied to simulate inner flow in the centrifugal pump at 3 different clocking positions of inducer relative to impeller. The pump mainly consisted of inlet pipe, inducer, impeller, diffuser and outlet pipe. When the angle between reference blade of inducer and reference blade of impeller was 53°, the relative circumferential position was called clocking position 0, named CL0; the clocking position number increased by 1 every increase of 40° clockwise. External characteristics, cavitation characteristics and vibration characteristics were analyzed. It was found that the external characteristics of centrifugal pump were greatly influenced by clocking effects. With the change of clocking position, the head and efficiency of pump first increased and then decreased; the head and efficiency were the highest at CL1. Comparing CL1 with CL0, the head was 1.3% higher and the efficiency was 0.39% greater; comparing CL1 with CL2, the head was 0.7% higher and the efficiency was 1.32% greater. It could also be found that the size and direction of velocity at the pressure side of inducer blade tail were greatly influenced by clocking effects. With the change of clocking position, the vortex at the pressure side of inducer blade tail gradually disappeared, indicating that the flow state was becoming better and better. Big and clear vertex was found at the pressure side of inducer blade tail at CL0 clocking position and no vertex at other clocking positions, which indicated that clocking position had the influence on the mutual interference of inducer and impeller, thus affecting the flow field inside the inducer, and appropriate clocking position could improve the flow field. At CL0 clocking position, radial forces were mainly distributed in a circle with the radius of 300 N. At CL1 clocking position, radial forces were mainly distributed in a ring with the radius of 100-300 N. At CL2 clocking position, radial forces were mainly distributed in an area with the radius of 100-320 N, which was “seven petal” shaped and coincided with the number of diffuser blade, indicating that the change of clocking position of the inducer had the influence on the interference between impeller and diffuser, thus affecting the size and direction of radial force to some extent. Besides, pressure pulsation frequency and amplitude of impeller and diffuser would also be directly affected, and the vibration may be caused by the interference between impeller and diffuser, or by the passing frequency of impeller, or by the “jet wake” of impeller. Reasonable clocking position can improve the cavitation performance of centrifugal pump. In summary, pump has the best overall performance at CL1.