提出了一种测定土壤有效硼的改进方法,用普通的聚四氟乙烯烧杯加盖直接煮沸法提取土壤中的有效硼,等离子体原子发射光谱法代替传统比色法测定提取溶液中有效硼的含量,方法检出限为0.02μg/g,准确度RE<5%,精密度RSD<6%,实际样品的加标回收率在92%~102%之间。方法操作简便,重现性好,准确度高,适合批量样品的检测。
提齣瞭一種測定土壤有效硼的改進方法,用普通的聚四氟乙烯燒杯加蓋直接煮沸法提取土壤中的有效硼,等離子體原子髮射光譜法代替傳統比色法測定提取溶液中有效硼的含量,方法檢齣限為0.02μg/g,準確度RE<5%,精密度RSD<6%,實際樣品的加標迴收率在92%~102%之間。方法操作簡便,重現性好,準確度高,適閤批量樣品的檢測。
제출료일충측정토양유효붕적개진방법,용보통적취사불을희소배가개직접자비법제취토양중적유효붕,등리자체원자발사광보법대체전통비색법측정제취용액중유효붕적함량,방법검출한위0.02μg/g,준학도RE<5%,정밀도RSD<6%,실제양품적가표회수솔재92%~102%지간。방법조작간편,중현성호,준학도고,괄합비량양품적검측。
The improved method was established for determination of soil available B by ICP-AES instead of traditional colorimetry, with ordinary Teflon Beaker of boiling direct extraction. The detection limits of the method was 0. 02 μg/g and accuracy ( RE ) was less than 5%. The relative standard deviation ( RSD ) was less than 6% and average recovery was 92% ~102%. The method was simple, stable, accurate and suitable for the analysis of mass samples.