亚表面腐蚀缺陷严重影响在役装备关键金属构件的完整性。本文提出一种新型脉冲涡流检测技术,即脉冲调制涡流检测技术,探究该技术在金属构件亚表面腐蚀缺陷检测和评估中的技术优势。首先,基于退化磁矢位法,建立了脉冲调制涡流检测金属构件亚表面腐蚀缺陷的高效有限元仿真模型,仿真分析了脉冲调制涡流检测信号及其特征与金属构件亚表面腐蚀缺陷深度间的关联规律,探究了该技术的优势性。同时,搭建了脉冲调制涡流/脉冲涡流双检测试验系统,通过试验,进一步探究两种技术在金属构件亚表面腐蚀缺陷检测中的优劣,试验结果验证了仿真分析结论。研究表明,对于金属构件亚表面腐蚀缺陷检测,脉冲调制涡流检测技术较脉冲涡流检测技术,具有更高的灵敏度。
亞錶麵腐蝕缺陷嚴重影響在役裝備關鍵金屬構件的完整性。本文提齣一種新型脈遲渦流檢測技術,即脈遲調製渦流檢測技術,探究該技術在金屬構件亞錶麵腐蝕缺陷檢測和評估中的技術優勢。首先,基于退化磁矢位法,建立瞭脈遲調製渦流檢測金屬構件亞錶麵腐蝕缺陷的高效有限元倣真模型,倣真分析瞭脈遲調製渦流檢測信號及其特徵與金屬構件亞錶麵腐蝕缺陷深度間的關聯規律,探究瞭該技術的優勢性。同時,搭建瞭脈遲調製渦流/脈遲渦流雙檢測試驗繫統,通過試驗,進一步探究兩種技術在金屬構件亞錶麵腐蝕缺陷檢測中的優劣,試驗結果驗證瞭倣真分析結論。研究錶明,對于金屬構件亞錶麵腐蝕缺陷檢測,脈遲調製渦流檢測技術較脈遲渦流檢測技術,具有更高的靈敏度。
아표면부식결함엄중영향재역장비관건금속구건적완정성。본문제출일충신형맥충와류검측기술,즉맥충조제와류검측기술,탐구해기술재금속구건아표면부식결함검측화평고중적기술우세。수선,기우퇴화자시위법,건립료맥충조제와류검측금속구건아표면부식결함적고효유한원방진모형,방진분석료맥충조제와류검측신호급기특정여금속구건아표면부식결함심도간적관련규률,탐구료해기술적우세성。동시,탑건료맥충조제와류/맥충와류쌍검측시험계통,통과시험,진일보탐구량충기술재금속구건아표면부식결함검측중적우렬,시험결과험증료방진분석결론。연구표명,대우금속구건아표면부식결함검측,맥충조제와류검측기술교맥충와류검측기술,구유경고적령민도。
Subsurface corrosion defect severely influences the integrity of crucial components of in-service apparatus.In light of this,this paper proposes a new pulsed eddy current technique (PEC),namely pulsed-modulation-based eddy current technique (PMEC),and intensively inves-tigates its advantages regarding inspection and evaluation of subsurface corrosion defect in metal-lic structures.The correlations of PMEC signals and their features with subsurface corrosion in different depths are firstly analyzed via the finite element analysis based on the numerical PMEC model established using reduced magnetic vector potential method.The advantages of PMEC over PEC are identified via simulations.In parallel,an experimental system implementing PMEC as well as PEC is built up.Through experiments,PMEC and PEC are further compared regarding inspection of subsurface corrosion defect in conductors.The experimental results are found to be in agreement with those from simulations.The results from both simulations and experiments in-dicate that compared with PEC,PMEC has higher sensitivity to subsurface corrosion defect in metallic structures.