中南大学学报(英文版)
中南大學學報(英文版)
중남대학학보(영문판)
Journal of Central South University
2015年
11期
4205-4212
,共8页
娄磊%吴万荣%王兆强%梁向京
婁磊%吳萬榮%王兆彊%樑嚮京
루뢰%오만영%왕조강%량향경
thermodynamics%hydraulic system%spool valve%bond graph%sloping U-shape notch
To increase the efficiency and reliability of the thermodynamics analysis of the spool valve, the precise function expression of the flow area for the sloping U-shape notch orifice versus the spool stroke and thermal-hydraulic bond graph based on the conservation of mass and energy were introduced. Subsequently, the connection rule for the bond graph elements and the method to construct the complete thermal-hydraulic system model were proposed. On the basis of heat transfer analysis of a typical hydraulic circuit containing the spool valve, the lumped parameter for mathematical model of the system was given. At last, the reliability of the mathematical model of the flow area and the thermal-hydraulic system for the sloping U-shape notch orifice on the spool were demonstrated by the test. The good agreement between the simulation results and experimental data demonstrates the validity of the modeling method.