目的:探讨基于原始数据的迭代重建(SAFIRE)技术在鼻部外伤性病变中的应用价值。方法鼻部外伤67例行CT 平扫,分别用 FBP 和 SAFIRE(强度1~5级)重建,对6种重建图像平均 CT 值、噪声、信号噪声比(SNR)、对比噪声比(CNR)、主观评分及病变检出情况对比分析。结果与 FBP 重建相比,SAFIRE(1~5级)重建后,噪声分别降低20.4%、31.4%、39.7%、46.5%、57.2%;SNR 分别提高33.3%、54.7%、75.4%、87.4%、101.4%;CNR 分别提高23.0%、36.4%、57.7%、87.4%、106.5%,差异有统计学意义(P<0.05)。图像主观评分 SAFIRE‐1和 SAFIRE‐5图像评分低于 FBP ,SAFIRE2‐4高于 FBP 重建, SAFIRE‐3评分最高,但6种重建图像的病变检出率一致。结论 CT 平扫结合 SAFIRE 重建技术在外伤性鼻部扫描中能有效降低图像噪声及提高图像质量,具有潜在降低扫描剂量的作用。
目的:探討基于原始數據的迭代重建(SAFIRE)技術在鼻部外傷性病變中的應用價值。方法鼻部外傷67例行CT 平掃,分彆用 FBP 和 SAFIRE(彊度1~5級)重建,對6種重建圖像平均 CT 值、譟聲、信號譟聲比(SNR)、對比譟聲比(CNR)、主觀評分及病變檢齣情況對比分析。結果與 FBP 重建相比,SAFIRE(1~5級)重建後,譟聲分彆降低20.4%、31.4%、39.7%、46.5%、57.2%;SNR 分彆提高33.3%、54.7%、75.4%、87.4%、101.4%;CNR 分彆提高23.0%、36.4%、57.7%、87.4%、106.5%,差異有統計學意義(P<0.05)。圖像主觀評分 SAFIRE‐1和 SAFIRE‐5圖像評分低于 FBP ,SAFIRE2‐4高于 FBP 重建, SAFIRE‐3評分最高,但6種重建圖像的病變檢齣率一緻。結論 CT 平掃結閤 SAFIRE 重建技術在外傷性鼻部掃描中能有效降低圖像譟聲及提高圖像質量,具有潛在降低掃描劑量的作用。
목적:탐토기우원시수거적질대중건(SAFIRE)기술재비부외상성병변중적응용개치。방법비부외상67례행CT 평소,분별용 FBP 화 SAFIRE(강도1~5급)중건,대6충중건도상평균 CT 치、조성、신호조성비(SNR)、대비조성비(CNR)、주관평분급병변검출정황대비분석。결과여 FBP 중건상비,SAFIRE(1~5급)중건후,조성분별강저20.4%、31.4%、39.7%、46.5%、57.2%;SNR 분별제고33.3%、54.7%、75.4%、87.4%、101.4%;CNR 분별제고23.0%、36.4%、57.7%、87.4%、106.5%,차이유통계학의의(P<0.05)。도상주관평분 SAFIRE‐1화 SAFIRE‐5도상평분저우 FBP ,SAFIRE2‐4고우 FBP 중건, SAFIRE‐3평분최고,단6충중건도상적병변검출솔일치。결론 CT 평소결합 SAFIRE 중건기술재외상성비부소묘중능유효강저도상조성급제고도상질량,구유잠재강저소묘제량적작용。
Objective To evaluate the value of the SAFIRE reconstruction technique for the nasal traumatic lesions .Methods Six‐ty‐seven patients with nasal traumas were scanned by the orbital scan and were reconstructed with FBP and SAFIRE (strength grade 1 to 5) respectively .Then a comparative analysis for six kinds of reconstructed images were conducted on the average CT value ,noise ,signal to noise ratio (SNR) ,contrast to noise ratio (CNR) ,subjective scoring and lesion detection .Results Compared with reconstruction by FBP , SAFIRE (strength grade 1 to 5)reconstruction ,for the noise ,decreased to 20 .4% ,31 .4% ,39 .7% ,46 .5% and 57 .2% respectively ;For the SNR ,increased to 33 .3% ,54 .7% ,75 .4% ,87 .4% and 101 .4% respectively ;For the CNR ,it also increased to 23 .0% ,36 .4% ,57 .7% , 87 .4% and 106 .5% respectively ;The difference was statistically significant (P< 0 .05) .For the images of SAFIRE‐1 and SAFIRE‐5 ,the image subjective scoring was lower than that by FBP ;for the images of SAFIRE‐2 and SAFIRE‐4 ,the image subjective scoring was higher than that by FBP ;and SAFIRE‐3 had the highest score .But for the rate of lesion detection ,all the images were the same .Conclusion CT scan combined SAFIRE reconstruction technique can decrease effectively the noise and increase the image quality in the traumatic nasal scan , as well as has a potential effect to decrease the scan dose .