中国电机工程学报
中國電機工程學報
중국전궤공정학보
Proceedings of the CSEE
2015年
11期
2681-2694,后插6
,共15页
吴婧%姚良忠%王志冰%李琰%杨波%曹远志
吳婧%姚良忠%王誌冰%李琰%楊波%曹遠誌
오청%요량충%왕지빙%리염%양파%조원지
多电压等级直流电网%模块化多电平换流器拓扑%直流故障电流阻断能力%单个子模块拓扑优化%桥臂拓扑优化%单相拓扑优化
多電壓等級直流電網%模塊化多電平換流器拓撲%直流故障電流阻斷能力%單箇子模塊拓撲優化%橋臂拓撲優化%單相拓撲優化
다전압등급직류전망%모괴화다전평환류기탁복%직류고장전류조단능력%단개자모괴탁복우화%교비탁복우화%단상탁복우화
DC grid with multi-voltage levels%modular multilevel converter (MMC) topology%DC fault current blocking capacity%single sub module topology optimization%arm topology optimization%single phase topology optimization
难于阻断直流侧故障电流是典型半桥模块化多电平换流器(half bridge sub module based modular multilevel converter,HBSM-MMC)的固有缺陷,严重影响该类型换流器在直流电网中的应用,因此开展具有直流故障电流阻断能力的 MMC 拓扑及控制技术研究意义重大.首先介绍典型HBSM-MMC的拓扑结构及工作原理,阐述其直流侧故障特性及影响机理,对比分析现阶段存在的直流侧故障清除方法及优缺点,指出基于换流器拓扑的自清除方法是解决直流侧故障电流阻断问题的最有效方法之一;通过对国内外MMC拓扑的调研,分别详细研究3类MMC优化拓扑结构及其直流故障隔离和电流阻断机理,对比分析3类优化拓扑的各项参数和功能实现的优缺点,为后续MMC技术在多端直流输电系统和多电压等级直流电网中的应用提供技术参考.
難于阻斷直流側故障電流是典型半橋模塊化多電平換流器(half bridge sub module based modular multilevel converter,HBSM-MMC)的固有缺陷,嚴重影響該類型換流器在直流電網中的應用,因此開展具有直流故障電流阻斷能力的 MMC 拓撲及控製技術研究意義重大.首先介紹典型HBSM-MMC的拓撲結構及工作原理,闡述其直流側故障特性及影響機理,對比分析現階段存在的直流側故障清除方法及優缺點,指齣基于換流器拓撲的自清除方法是解決直流側故障電流阻斷問題的最有效方法之一;通過對國內外MMC拓撲的調研,分彆詳細研究3類MMC優化拓撲結構及其直流故障隔離和電流阻斷機理,對比分析3類優化拓撲的各項參數和功能實現的優缺點,為後續MMC技術在多耑直流輸電繫統和多電壓等級直流電網中的應用提供技術參攷.
난우조단직류측고장전류시전형반교모괴화다전평환류기(half bridge sub module based modular multilevel converter,HBSM-MMC)적고유결함,엄중영향해류형환류기재직류전망중적응용,인차개전구유직류고장전류조단능력적 MMC 탁복급공제기술연구의의중대.수선개소전형HBSM-MMC적탁복결구급공작원리,천술기직류측고장특성급영향궤리,대비분석현계단존재적직류측고장청제방법급우결점,지출기우환류기탁복적자청제방법시해결직류측고장전류조단문제적최유효방법지일;통과대국내외MMC탁복적조연,분별상세연구3류MMC우화탁복결구급기직류고장격리화전류조단궤리,대비분석3류우화탁복적각항삼수화공능실현적우결점,위후속MMC기술재다단직류수전계통화다전압등급직류전망중적응용제공기술삼고.
Incapability of blocking DC fault current is an inherent defect of typical half bridge sub module based modular multilevel converter (HBSM-MMC), which seriously affects its application in DC grid. Thus, the study on the topology and control technology of MMC with DC fault current blocking capacity is of great significance. This paper first introduced the topology and operation principle of typical HBSM-MMC, described the fault characteristics of its DC side and influence mechanism, analyzed the existing DC side fault clearing methods at present and their advantages and disadvantages, and pointed out that self-clearing by converter based on its topology is an effective method to solve this problem. Through technical survey, this paper studied and presented three types of optimized MMC topology and their DC fault isolation and current blocking mechanism, then compared the indexes of them and analyzed their merits and drawbacks of function realization, thus it provides technical reference for further study and application of MMC technology in multi-terminal DC transmission system and DC grid with multi voltage levels.