工程设计学报
工程設計學報
공정설계학보
Chinese Journal of Engineering Design
2015年
5期
487-492
,共6页
孙立军%张子磐%蔡兵新%刘大伟%徐天室
孫立軍%張子磐%蔡兵新%劉大偉%徐天室
손립군%장자반%채병신%류대위%서천실
流量计量%流量标准装置%电动换向器%不确定度%步进电机
流量計量%流量標準裝置%電動換嚮器%不確定度%步進電機
류량계량%류량표준장치%전동환향기%불학정도%보진전궤
metrology%standard flow facility%electric flow diverter%uncertainty%step motor
为提高换向器的性能和减小不确定度,在分析换向器结构、换向过程、不确定度影响因素的基础上,提出了一种步进电机直接驱动分水器旋转换向的电动换向器结构,利用 PCI板卡控制其旋转换向动作,在不同流量点可采用不同速度,具有较好的正反行程的对称性.研究了换向器的控制策略,设计搭建了多口径的换向器测试平台,进行了DN50,DN80口径换向器的行程差法实验测试.实验数据表明,电动换向器的不确定度可达到0.0012%的水平.这种结构降低了运行时的噪声,提高了不确定度的水平,进而可以降低液体流量标准装置的整体不确定度.
為提高換嚮器的性能和減小不確定度,在分析換嚮器結構、換嚮過程、不確定度影響因素的基礎上,提齣瞭一種步進電機直接驅動分水器鏇轉換嚮的電動換嚮器結構,利用 PCI闆卡控製其鏇轉換嚮動作,在不同流量點可採用不同速度,具有較好的正反行程的對稱性.研究瞭換嚮器的控製策略,設計搭建瞭多口徑的換嚮器測試平檯,進行瞭DN50,DN80口徑換嚮器的行程差法實驗測試.實驗數據錶明,電動換嚮器的不確定度可達到0.0012%的水平.這種結構降低瞭運行時的譟聲,提高瞭不確定度的水平,進而可以降低液體流量標準裝置的整體不確定度.
위제고환향기적성능화감소불학정도,재분석환향기결구、환향과정、불학정도영향인소적기출상,제출료일충보진전궤직접구동분수기선전환향적전동환향기결구,이용 PCI판잡공제기선전환향동작,재불동류량점가채용불동속도,구유교호적정반행정적대칭성.연구료환향기적공제책략,설계탑건료다구경적환향기측시평태,진행료DN50,DN80구경환향기적행정차법실험측시.실험수거표명,전동환향기적불학정도가체도0.0012%적수평.저충결구강저료운행시적조성,제고료불학정도적수평,진이가이강저액체류량표준장치적정체불학정도.
In order to reduce uncertainty and improve performance of flow diverter ,on the basis of analyzing the structure of the flow diverter ,the process of transfer and the factors impacting the uncertainty ,a structure of electric flow diverter was put forward .A step motor directly drove the water separator to turn and realize the direction convert .The action of turning and direction con‐vert was fully controlled by PCI cards .It could work at different flow point with different rate and had a good performance on the symmetry of forward and reverse process .The control strate‐gy of the electric flow diverter w as also investigated .A test bench for multi‐caliber flow diverter was designed and built .The experimental tests of DN50 and DN80 flow diverters were carried out .It suggested , by the test data , the uncertainty of the electric flow diverter could reach 0 .0012% ,which could reduce the uncertainty of the diverter and noise .It will eventually reduce the overall uncertainty of liquid flow facility .