文昌13-1/2油田液化石油气(LPG)回收项目是中海石油(中国)有限公司湛江分公司首个海上 LPG回收项目。近年来文昌油田 LPG产品时而会发生铜腐测试不合格情况,本文通过对 LPG 系统硫化氢检测,LPG气样总硫含量测试以及铜片腐蚀产物的能谱测试,发现文昌油田 LPG气样铜腐超标和硫含量超标有关。根据海上油田生产环境特点,拟采取湿法脱硫技术,直接加注脱硫剂的方法治理铜腐不合格问题。现场试验加药点选在进口压缩机进口,这样既可以给脱硫剂与硫化氢反应提供空间和时间,又可以在 LPG系统较前端将硫化氢治理到较低水平,防止了硫化氢在 LPG系统中的扩散。液化气脱硫剂以加注量50mL/min,在现场实践应用的一个月的时间里,可以有效地将铜腐指标从2 a降低到1 a,确保 LPG产品符合国标标准要求。
文昌13-1/2油田液化石油氣(LPG)迴收項目是中海石油(中國)有限公司湛江分公司首箇海上 LPG迴收項目。近年來文昌油田 LPG產品時而會髮生銅腐測試不閤格情況,本文通過對 LPG 繫統硫化氫檢測,LPG氣樣總硫含量測試以及銅片腐蝕產物的能譜測試,髮現文昌油田 LPG氣樣銅腐超標和硫含量超標有關。根據海上油田生產環境特點,擬採取濕法脫硫技術,直接加註脫硫劑的方法治理銅腐不閤格問題。現場試驗加藥點選在進口壓縮機進口,這樣既可以給脫硫劑與硫化氫反應提供空間和時間,又可以在 LPG繫統較前耑將硫化氫治理到較低水平,防止瞭硫化氫在 LPG繫統中的擴散。液化氣脫硫劑以加註量50mL/min,在現場實踐應用的一箇月的時間裏,可以有效地將銅腐指標從2 a降低到1 a,確保 LPG產品符閤國標標準要求。
문창13-1/2유전액화석유기(LPG)회수항목시중해석유(중국)유한공사담강분공사수개해상 LPG회수항목。근년래문창유전 LPG산품시이회발생동부측시불합격정황,본문통과대 LPG 계통류화경검측,LPG기양총류함량측시이급동편부식산물적능보측시,발현문창유전 LPG기양동부초표화류함량초표유관。근거해상유전생산배경특점,의채취습법탈류기술,직접가주탈류제적방법치리동부불합격문제。현장시험가약점선재진구압축궤진구,저양기가이급탈류제여류화경반응제공공간화시간,우가이재 LPG계통교전단장류화경치리도교저수평,방지료류화경재 LPG계통중적확산。액화기탈류제이가주량50mL/min,재현장실천응용적일개월적시간리,가이유효지장동부지표종2 a강저도1 a,학보 LPG산품부합국표표준요구。
Wen1 3-1/2 oil field liquefied petroleum gas (LPG ) recycling proj ect is the first offshore LPG recycling project in CNOOC (China)Co.,Ltd.Zhanjiang branch.In recent years, LPG gas copper corrosion exceeding occurs sometimes.By detecting hydrogen sulfide,total sulfur content of LPG gas sample and testing copper corrosion product through energy spectrum test, Wen1 3-1/2 oil field LPG copper corrosion exceeding is concerned with sulfur content exceeding.According to the characteristics of production conditions in offshore oil field,we propose to adopt wet desulfuring technologies———direct inj ection of hydrogen sulfide scavenger to solve unqualified copper corrosion problems.Field test inj ection point is set on compressor entrance,which can provide space and time for reaction between the hydrogen sulfide scavenger with hydrogen sulfide and can also manage hydrogen sulfide to lower levels from upstream of LPG systems,preventing the proliferation of hydrogen sulfide in the LPG system.Liquefied petroleum gas desulfurizer goes with filling volume 50mL/min.During a month’s time of field test,copper corrosion index can be effectively decreased to 1a from 2a,which can ensure that LPG products comply with national standard.