中国全科医学
中國全科醫學
중국전과의학
Chinese General Practice
2015年
33期
4144-4146,4147
,共4页
余转%王菁哲%魏静%张哲%薛玉%陈宝定
餘轉%王菁哲%魏靜%張哲%薛玉%陳寶定
여전%왕정철%위정%장철%설옥%진보정
超声检查,多普勒,彩色%妊娠中期%胎儿%大脑中动脉%血流动力学
超聲檢查,多普勒,綵色%妊娠中期%胎兒%大腦中動脈%血流動力學
초성검사,다보륵,채색%임신중기%태인%대뇌중동맥%혈류동역학
Ultrasonography,Doppler,color%Pregnancy trimester,second%Fetus%Middle cerebral artery%Hemodynamics
目的:探讨彩色多普勒超声检测妊娠中期胎儿大脑中动脉 M1段不同节段(M1段近中1/3处、M1段远端)血流动力学指标的差异,探查最佳的检测部位。方法选取2014年12月—2015年5月在江苏大学附属医院超声科行妊娠中期胎儿结构筛查的孕妇124例为研究对象。检测胎儿大脑中动脉 M1段近中1/3处和 M1段远端的血流动力学指标〔收缩期峰值流速(PSV)、阻力指数(RI)、搏动指数(PI)和收缩期峰值流速/舒张末期流速(S/ D)〕。结果排除胎儿宫内活动频繁、脐带绕颈、羊水量异常等孕妇16例,最终共有108例孕妇纳入本研究,成功率为87.1%。彩色多普勒超声胎儿大脑中动脉 M1段不同节段的血流频谱均呈锯齿状,在整个心动周期中均为单向血流,舒张期无反向血流信号。大脑中动脉 M1段近中1/3处 PSV、RI、PI、S/ D 高于 M1段远端(P <0.05)。结论妊娠中期胎儿大脑中动脉 M1段近中1/3处血流动力学指标高于 M1段远端,M1段近中1/3处得到的血流动力学指标更加准确客观。
目的:探討綵色多普勒超聲檢測妊娠中期胎兒大腦中動脈 M1段不同節段(M1段近中1/3處、M1段遠耑)血流動力學指標的差異,探查最佳的檢測部位。方法選取2014年12月—2015年5月在江囌大學附屬醫院超聲科行妊娠中期胎兒結構篩查的孕婦124例為研究對象。檢測胎兒大腦中動脈 M1段近中1/3處和 M1段遠耑的血流動力學指標〔收縮期峰值流速(PSV)、阻力指數(RI)、搏動指數(PI)和收縮期峰值流速/舒張末期流速(S/ D)〕。結果排除胎兒宮內活動頻繁、臍帶繞頸、羊水量異常等孕婦16例,最終共有108例孕婦納入本研究,成功率為87.1%。綵色多普勒超聲胎兒大腦中動脈 M1段不同節段的血流頻譜均呈鋸齒狀,在整箇心動週期中均為單嚮血流,舒張期無反嚮血流信號。大腦中動脈 M1段近中1/3處 PSV、RI、PI、S/ D 高于 M1段遠耑(P <0.05)。結論妊娠中期胎兒大腦中動脈 M1段近中1/3處血流動力學指標高于 M1段遠耑,M1段近中1/3處得到的血流動力學指標更加準確客觀。
목적:탐토채색다보륵초성검측임신중기태인대뇌중동맥 M1단불동절단(M1단근중1/3처、M1단원단)혈류동역학지표적차이,탐사최가적검측부위。방법선취2014년12월—2015년5월재강소대학부속의원초성과행임신중기태인결구사사적잉부124례위연구대상。검측태인대뇌중동맥 M1단근중1/3처화 M1단원단적혈류동역학지표〔수축기봉치류속(PSV)、조력지수(RI)、박동지수(PI)화수축기봉치류속/서장말기류속(S/ D)〕。결과배제태인궁내활동빈번、제대요경、양수량이상등잉부16례,최종공유108례잉부납입본연구,성공솔위87.1%。채색다보륵초성태인대뇌중동맥 M1단불동절단적혈류빈보균정거치상,재정개심동주기중균위단향혈류,서장기무반향혈류신호。대뇌중동맥 M1단근중1/3처 PSV、RI、PI、S/ D 고우 M1단원단(P <0.05)。결론임신중기태인대뇌중동맥 M1단근중1/3처혈류동역학지표고우 M1단원단,M1단근중1/3처득도적혈류동역학지표경가준학객관。
Objective To explore the difference in the hemodynamic parameters of different parts of M1 segment of fetal middle cerebral artery(the 1 / 3 point of M1 segment nearer to the middle point and the far end of M1 segment),in order to find the optimal detection site. Methods 124 pregnant women who received screening for fetus structure in the Department of Ultrasound of the Affiliated Hospital of Jiangsu University from December 2014 to May 2015 were enrolled in the study. The hemodynamic parameters(PSV,RI,PI and S/ D)of different parts of M1 segment of fetal middle cerebral artery(1 / 3 points of M1 segment nearer to the middle point and the far end of M1 segment)were detected. Results Apart from 16 cases of pregnant women with the fetal frequent activities,umbilical cord around the neck and amniotic fluid volume abnormality,108 normal fetal were included,with a success rate of 87. 1%. Blood flow frequency spectrum of different parts of the M1 segment of fetal middle cerebral artery with color ultrasound was one - way flow ofindentation throughout the cardiac cycle,without diastolic reverse blood flow signals. Hemodynamic parameters,such as PSV,RI,PI and S/ D,at the 1 / 3 point of M1 segment nearer to the middle point,were higher than those at the far end of M1 segment(P < 0. 05). Conclusion Conclusion hemodynamic parameters at the 1 / 3 point of M1 segment of fetal middle cerebral artery nearer to the middle point are higher than those at the far end of M1 segment,thus the hemodynamic parameters at the 1 / 3 point are more accurate and objective.