测试%电解单元槽%电压%偏差
測試%電解單元槽%電壓%偏差
측시%전해단원조%전압%편차
measurement%electrolysis unit cell%voltage%deviation
通过理论分析和计算,结合实际情况提出了增加引线消除铜排电压和改接线降低铜排电压这两种减小电解槽单元槽电压测量偏差的解决方案,并分析了每种方案的优缺点。
通過理論分析和計算,結閤實際情況提齣瞭增加引線消除銅排電壓和改接線降低銅排電壓這兩種減小電解槽單元槽電壓測量偏差的解決方案,併分析瞭每種方案的優缺點。
통과이론분석화계산,결합실제정황제출료증가인선소제동배전압화개접선강저동배전압저량충감소전해조단원조전압측량편차적해결방안,병분석료매충방안적우결점。
On the basis of theoretical analysis , calculation and practical situations , two solutions to the measurement deviation of voltage of electrolysis unit cells , i.e.adding lead wires to eliminate copper busbar voltage and changing connection wires to reduce copper busbar voltage were proposed .Advantages and disadvantages of the two solutions were analyzed .