针对被控对象的大惯性、大迟延、非线性等特性,基于PID控制抗干扰性强和无模型自适应控制(MFAC)对惯性和延迟系统具有较强适应能力的特点,设计了一种带死区的 MFAC-PID串级控制系统。以米东热电厂选择性非催化还原(SNCR)烟气脱硝系统为对象,建立了系统仿真模型,采用MATLAB软件将MFAC-PID与PID控制进行仿真比较。结果表明:在阶跃扰动和模型失配情况下,带死区的MFAC-PID串级控制系统较常规PID串级控制系统,超调更小,调节时间更短;在机组负荷扰动下,带死区的 MFAC-PID 串级控制系统波动很小。因此,带死区的MFAC-PID串级控制系统能够更好地适应对象参数的变化,具有较强的鲁棒性和自适应性。
針對被控對象的大慣性、大遲延、非線性等特性,基于PID控製抗榦擾性彊和無模型自適應控製(MFAC)對慣性和延遲繫統具有較彊適應能力的特點,設計瞭一種帶死區的 MFAC-PID串級控製繫統。以米東熱電廠選擇性非催化還原(SNCR)煙氣脫硝繫統為對象,建立瞭繫統倣真模型,採用MATLAB軟件將MFAC-PID與PID控製進行倣真比較。結果錶明:在階躍擾動和模型失配情況下,帶死區的MFAC-PID串級控製繫統較常規PID串級控製繫統,超調更小,調節時間更短;在機組負荷擾動下,帶死區的 MFAC-PID 串級控製繫統波動很小。因此,帶死區的MFAC-PID串級控製繫統能夠更好地適應對象參數的變化,具有較彊的魯棒性和自適應性。
침대피공대상적대관성、대지연、비선성등특성,기우PID공제항간우성강화무모형자괄응공제(MFAC)대관성화연지계통구유교강괄응능력적특점,설계료일충대사구적 MFAC-PID천급공제계통。이미동열전엄선택성비최화환원(SNCR)연기탈초계통위대상,건립료계통방진모형,채용MATLAB연건장MFAC-PID여PID공제진행방진비교。결과표명:재계약우동화모형실배정황하,대사구적MFAC-PID천급공제계통교상규PID천급공제계통,초조경소,조절시간경단;재궤조부하우동하,대사구적 MFAC-PID 천급공제계통파동흔소。인차,대사구적MFAC-PID천급공제계통능구경호지괄응대상삼수적변화,구유교강적로봉성화자괄응성。
According to such characteristics of the controlled obj ect as large inertia,large delay and nonlin-earity,a model free adaptive control and PED (MFAC-PID)cascade control system with dead zone was de-signed,on the basis of anti interference of PID control and strong adaptability of model free adaptive con-trol (MFAC)to inertia and delay system.Moreover,taking the selective non-catalytic reduction (SNCR) flue gas denitration system in Midong Thermal Power Plant as the obj ect,the system simulation model was established,and the MATLAB software was applied to compare the two control methods.The results show that,under conditions with step disturbance and model mismatch,the MFAC-PID cascade control system with dead zone has smaller overshoot and shorter settling time than the conventional PID cascade control system.Under unit load disturbance condition,the MFAC-PID cascade control system with dead zone has very small fluctuation.Therefore,the MFAC-PID cascade control system with dead zone can better adapt to the changes of obj ect parameters,and has strong robustness and adaptability.