黑龙江电力
黑龍江電力
흑룡강전력
Heilongjiang Electric Power
2015年
5期
414-419
,共6页
张新%李少华%刘彦鹏%郭婷婷
張新%李少華%劉彥鵬%郭婷婷
장신%리소화%류언붕%곽정정
电站冷凝器%腐蚀%电化学%加速试验
電站冷凝器%腐蝕%電化學%加速試驗
전참냉응기%부식%전화학%가속시험
power station condenser%corrosion%electrochemistry%accelerated test
为了有效解决国内外电站冷凝器管材腐蚀造成的泄漏问题,重点阐述了管材腐蚀机理、腐蚀形式,以及冷凝器管材腐蚀行为的加速试验方法,指出了室内加速试验是最为常用的模拟服役环境腐蚀加速试验方法,提出了今后电站冷凝器管材腐蚀研究及测试方法的发展趋势.
為瞭有效解決國內外電站冷凝器管材腐蝕造成的洩漏問題,重點闡述瞭管材腐蝕機理、腐蝕形式,以及冷凝器管材腐蝕行為的加速試驗方法,指齣瞭室內加速試驗是最為常用的模擬服役環境腐蝕加速試驗方法,提齣瞭今後電站冷凝器管材腐蝕研究及測試方法的髮展趨勢.
위료유효해결국내외전참냉응기관재부식조성적설루문제,중점천술료관재부식궤리、부식형식,이급냉응기관재부식행위적가속시험방법,지출료실내가속시험시최위상용적모의복역배경부식가속시험방법,제출료금후전참냉응기관재부식연구급측시방법적발전추세.
In order to solve the leakage of power station condenser caused by the material corrosion at home and a-broad, this paper focused on expounding the corrosion mechanism and forms of the pipes, and the accelerated cor-rosion test method of condenser tube, pointing out that the indoor accelerated test was direction of development of the simulated service environment corrosion test method, and proposed the future development trend of power sta-tion condenser pipe corrosion research and testing methods.