化工设计通讯
化工設計通訊
화공설계통신
Chemical Engineering Design Communications
2015年
5期
56-58
,共3页
镉%流动注射%分光光度法
鎘%流動註射%分光光度法
력%류동주사%분광광도법
cadmium%flow injection anaiysis%spectorphotometry
报道了 Cd-KI-乙基紫 FIA 分光光度法测定镉的新方法。镉的测定范围为0-0.5μg/ml,摩尔吸光系数ε530=3.5×105 L·mol-1·cm-1,精密度 RSD 为0.72%,分析速度达120样/h。用所建立的方法分析环境水样中的镉,回收率在99%-102%之间,结果满意。
報道瞭 Cd-KI-乙基紫 FIA 分光光度法測定鎘的新方法。鎘的測定範圍為0-0.5μg/ml,摩爾吸光繫數ε530=3.5×105 L·mol-1·cm-1,精密度 RSD 為0.72%,分析速度達120樣/h。用所建立的方法分析環境水樣中的鎘,迴收率在99%-102%之間,結果滿意。
보도료 Cd-KI-을기자 FIA 분광광도법측정력적신방법。력적측정범위위0-0.5μg/ml,마이흡광계수ε530=3.5×105 L·mol-1·cm-1,정밀도 RSD 위0.72%,분석속도체120양/h。용소건립적방법분석배경수양중적력,회수솔재99%-102%지간,결과만의。
A method of determination of cadmium by flow injection analysis spectrophotometery was studied.The experimental conditons have been optimized.Beer’s law is obeyed in the range of 0-0.5μg/ml for cadmium,and theε530 =3.5×105 L.mol-1.cm-1 ,RSD=0.72%(n=11).The method can be used for the determination of cadmium in environmental water and the recovers were 99%-102%.Sampling frequency was 120/h.