X射线弯晶谱仪作为托卡马克装置等离子体温度和旋转速度等参数诊断测量的重要手段之一,通常利用单晶体衍射分光来测量某种特定杂质的特征谱,这也限制了弯晶谱仪所能测量的等离子体温度范围。为解决更高温度等离子体测量问题,有效提高目前弯晶谱仪诊断系统温度测量范围,用双晶体代替原有单晶体,通过选择合适的晶体和 Bragg 衍射角组合,利用同一个探测器同时测量类氢和类氦的氩离子光谱,实现更高更宽温度范围测量。本文就东方超环(Experimental Advanced Superconducting Tokamak, EAST)弯晶谱仪双晶体应用方面的设计和技术实现进行了阐述,并首次在 EAST 装置上成功实现了氩离子类氦和类氢谱线的测量,利用类氦线和类氢线拟合得到的氩离子温度非常接近,验证了双晶体结构的可行性。
X射線彎晶譜儀作為託卡馬剋裝置等離子體溫度和鏇轉速度等參數診斷測量的重要手段之一,通常利用單晶體衍射分光來測量某種特定雜質的特徵譜,這也限製瞭彎晶譜儀所能測量的等離子體溫度範圍。為解決更高溫度等離子體測量問題,有效提高目前彎晶譜儀診斷繫統溫度測量範圍,用雙晶體代替原有單晶體,通過選擇閤適的晶體和 Bragg 衍射角組閤,利用同一箇探測器同時測量類氫和類氦的氬離子光譜,實現更高更寬溫度範圍測量。本文就東方超環(Experimental Advanced Superconducting Tokamak, EAST)彎晶譜儀雙晶體應用方麵的設計和技術實現進行瞭闡述,併首次在 EAST 裝置上成功實現瞭氬離子類氦和類氫譜線的測量,利用類氦線和類氫線擬閤得到的氬離子溫度非常接近,驗證瞭雙晶體結構的可行性。
X사선만정보의작위탁잡마극장치등리자체온도화선전속도등삼수진단측량적중요수단지일,통상이용단정체연사분광래측량모충특정잡질적특정보,저야한제료만정보의소능측량적등리자체온도범위。위해결경고온도등리자체측량문제,유효제고목전만정보의진단계통온도측량범위,용쌍정체대체원유단정체,통과선택합괄적정체화 Bragg 연사각조합,이용동일개탐측기동시측량류경화류양적아리자광보,실현경고경관온도범위측량。본문취동방초배(Experimental Advanced Superconducting Tokamak, EAST)만정보의쌍정체응용방면적설계화기술실현진행료천술,병수차재 EAST 장치상성공실현료아리자류양화류경보선적측량,이용류양선화류경선의합득도적아리자온도비상접근,험증료쌍정체결구적가행성。
Background:X-ray curved-crystal spectrometer, as one of important diagnostic tool for measuring the plasma temperature and rotation velocity of the tokamak, is usually based on the satellite spectra of some special kind of impurity by single-crystal diffraction, which limits the temperature range to be measured simultaneously.Purpose: This study aims to effectively broaden the temperature range of the spectrometers, an assembly of double-crystal was designed to replace the previous of single-crystal.Methods: The two crystals of the assembly having the similar Bragg angles were installed on the same pedestal, which could make the spectra recorded on the same detector. Consideration and technology route of the double-crystal were described and analyzed together with the experimental tests on the Experimental Advanced Superconducting Tokamak (EAST).Results: Experimental results on the double-crystal X-ray spectrometer showed that the He-like and H-like Ar spectra were obtained for the first time, and the ion Ar temperatures calculated by two kinds of spectra were in good consistence within a certain error range. Conclusion:The application of double-crystal for X-ray curved-crystal spectrometers on EAST proposed in this paper is applicable and feasible.