辅助供电系统可靠性对动车组的安全正常运行至关重要。为研究其可靠性,深入分析了 CRH3型动车组辅助供电系统各组成结构及逻辑功能关系,建立了辅助供电系统可靠性框图模型。在此基础上,依据系统可靠性理论与武广高铁 CRH3型动车组辅助供电系统故障统计数据,分析计算 CRH3型动车组辅助供电系统各部件的故障率和可靠度,并结合最小路集不交化算法,计算评估了 CRH3型动车组辅助供电系统的可靠性。为进一步提高系统可靠性,提出了在辅助供电系统关键设备配电网络中增加热备冗余支路的优化方案,计算结果验证了所提出方案的有效性。研究结果为 CRH3型动车组辅助供电系统维护维修及可靠性优化提供依据。
輔助供電繫統可靠性對動車組的安全正常運行至關重要。為研究其可靠性,深入分析瞭 CRH3型動車組輔助供電繫統各組成結構及邏輯功能關繫,建立瞭輔助供電繫統可靠性框圖模型。在此基礎上,依據繫統可靠性理論與武廣高鐵 CRH3型動車組輔助供電繫統故障統計數據,分析計算 CRH3型動車組輔助供電繫統各部件的故障率和可靠度,併結閤最小路集不交化算法,計算評估瞭 CRH3型動車組輔助供電繫統的可靠性。為進一步提高繫統可靠性,提齣瞭在輔助供電繫統關鍵設備配電網絡中增加熱備冗餘支路的優化方案,計算結果驗證瞭所提齣方案的有效性。研究結果為 CRH3型動車組輔助供電繫統維護維脩及可靠性優化提供依據。
보조공전계통가고성대동차조적안전정상운행지관중요。위연구기가고성,심입분석료 CRH3형동차조보조공전계통각조성결구급라집공능관계,건립료보조공전계통가고성광도모형。재차기출상,의거계통가고성이론여무엄고철 CRH3형동차조보조공전계통고장통계수거,분석계산 CRH3형동차조보조공전계통각부건적고장솔화가고도,병결합최소로집불교화산법,계산평고료 CRH3형동차조보조공전계통적가고성。위진일보제고계통가고성,제출료재보조공전계통관건설비배전망락중증가열비용여지로적우화방안,계산결과험증료소제출방안적유효성。연구결과위 CRH3형동차조보조공전계통유호유수급가고성우화제공의거。
Reliability of the auxiliary power system is critical to the safe and normal operation of electric multi-ple units (EMUs).In order to study such reliability,the reliability block diagram (RBD)model of the auxilia-ry power system was established after a thorough analysis was made on the structure and logic function rela-tionships of the auxiliary power system of CRH3 EMUs.On the basis of the model,and the system reliability theory as well as the statistical data of failures of the auxiliary power system of CRH3 EMUs running on the Wuhan-Guangzhou high-speed railway,the fault rate and reliability of the components of the auxiliary power system were calculated.Combined with disjoint minimal path set method,the reliability of the auxiliary power system was evaluated.For the further improvement of the system reliability,the optimization scheme was put forward to add hot backup redundancy branch in the power distribution network for the key equipment of the auxiliary power system.The calculation results verified the validity of the proposed scheme.The research re-sults provide a basis for reliability optimization,maintenance and repair of the auxiliary power system of CRH3 EMUs.