采用静态失重法、动电位极化曲线法和交流阻抗法研究了十八烷基三甲基氯化铵( STAC)在硫酸介质中对A3钢的缓蚀行为。探讨了其对A3钢的缓蚀作用机理;并用扫描电子显微镜( SEM)观察腐蚀表面的形貌。结果表明,不同温度下,缓蚀率随STAC浓度增大而增大;在浓度为10 mg/L时,失重缓蚀率达80%以上。极化曲线试验结果显示STAC是一种以控制阳极反应为主的混合型缓蚀剂;且静态失重法、动电位极化曲线法和交流阻抗法试验结果相一致。 STAC在A3钢表面的吸附服从校正后的Langmiur吸附等温模型,是一种化学吸附作用的自发吸附;且吸附是一个放热的熵减小的过程。扫描电镜实验结果表明,STAC能有效抑制硫酸对A3钢的腐蚀。
採用靜態失重法、動電位極化麯線法和交流阻抗法研究瞭十八烷基三甲基氯化銨( STAC)在硫痠介質中對A3鋼的緩蝕行為。探討瞭其對A3鋼的緩蝕作用機理;併用掃描電子顯微鏡( SEM)觀察腐蝕錶麵的形貌。結果錶明,不同溫度下,緩蝕率隨STAC濃度增大而增大;在濃度為10 mg/L時,失重緩蝕率達80%以上。極化麯線試驗結果顯示STAC是一種以控製暘極反應為主的混閤型緩蝕劑;且靜態失重法、動電位極化麯線法和交流阻抗法試驗結果相一緻。 STAC在A3鋼錶麵的吸附服從校正後的Langmiur吸附等溫模型,是一種化學吸附作用的自髮吸附;且吸附是一箇放熱的熵減小的過程。掃描電鏡實驗結果錶明,STAC能有效抑製硫痠對A3鋼的腐蝕。
채용정태실중법、동전위겁화곡선법화교류조항법연구료십팔완기삼갑기록화안( STAC)재류산개질중대A3강적완식행위。탐토료기대A3강적완식작용궤리;병용소묘전자현미경( SEM)관찰부식표면적형모。결과표명,불동온도하,완식솔수STAC농도증대이증대;재농도위10 mg/L시,실중완식솔체80%이상。겁화곡선시험결과현시STAC시일충이공제양겁반응위주적혼합형완식제;차정태실중법、동전위겁화곡선법화교류조항법시험결과상일치。 STAC재A3강표면적흡부복종교정후적Langmiur흡부등온모형,시일충화학흡부작용적자발흡부;차흡부시일개방열적적감소적과정。소묘전경실험결과표명,STAC능유효억제류산대A3강적부식。
The inhibition behavior of stearyltrimethylammonium chloride (STAC) for A3 steel in the presence of sulphuric acid solution was evaluated by the static weight loss methods, the potentiodynamic polarization curves and the electrical impedance spectroscopy ( EIS) , as well as the inhibition mechanism of STAC was also discussed.Then the surface morphology after the corrosion test was observed by scanning electron microscopy( SEM).The experimen-tal results revealed that the inhibition efficiency was found to increase with the increase of STAC concentration of STAC, and that the inhibition efficiency of static weight loss was up to 80%when the concentration of STAC was 10 mg/L at different temperatures.Polarization curve results showed that STAC was a mix-type inhibitor which mainly inhibited anodic process, moreover, the anti-corrosion performances determinated by the static weight loss methods, the potentiodynamic polarization curve and EIS were almost consistent.The adsorption of STAC on A3 steel surface a-bided the calibrated Langmuir′s adsorption isotherm.The adsorption is a spontaneous, exothermic process of reduced entropy.The results of scanning electron microscopy( SEM) test showed that the process of corrosion reaction was ef-fectively retarded by STAC.