目的:通过模拟单纯性肾囊肿的体模模型,评估管电流对肾囊肿假性强化的影响。材料与方法使用10%葡萄糖液及一定浓度的含碘溶液,分别模拟平扫、中等强化及最大强化程度肾实质背景浓度。囊肿直径分别为6 mm、10 mm、15 mm,依据管电流不同分为A组119 mAs、B组178 mAs、C组297 mAs,管电压均为120 kV。以CT增加值10 HU为临界值,评估不同条件下囊肿有无假性强化。结果 A组仅在240 HU背景浓度下出现假性强化,且直径6 mm的囊肿最显著,为21 HU。B组直径10 mm和6 mm的囊肿在180 HU和240 HU背景下均出现假性强化,差值最大为240 HU直径6 mm的囊肿,为20.4 HU。C组仅直径6 mm的囊肿在125 HU和240 HU背景浓度下有假性强化。囊肿假性强化受背景浓度(F=17.587,P<0.01)和囊肿直径(F=4.214,P<0.05)较大,背景浓度越高,直径越小,假性强化越明显。随着管电流增加,CT容积剂量指数增加,假性强化值越来越小,但各组中不同背景浓度及不同直径的囊肿假性强化出现几率无明显规律。结论增加CT扫描管电流不能完全消除囊肿假性强化的产生。较高的背景浓度和较小的囊肿直径是产生假性强化的重要因素。但增加管电流可以在一定程度上减少假性强化发生的几率。对于体重较重者,适当增加管电流以改善图像质量、减少肾囊肿假性强化发生的可能是必要的。
目的:通過模擬單純性腎囊腫的體模模型,評估管電流對腎囊腫假性彊化的影響。材料與方法使用10%葡萄糖液及一定濃度的含碘溶液,分彆模擬平掃、中等彊化及最大彊化程度腎實質揹景濃度。囊腫直徑分彆為6 mm、10 mm、15 mm,依據管電流不同分為A組119 mAs、B組178 mAs、C組297 mAs,管電壓均為120 kV。以CT增加值10 HU為臨界值,評估不同條件下囊腫有無假性彊化。結果 A組僅在240 HU揹景濃度下齣現假性彊化,且直徑6 mm的囊腫最顯著,為21 HU。B組直徑10 mm和6 mm的囊腫在180 HU和240 HU揹景下均齣現假性彊化,差值最大為240 HU直徑6 mm的囊腫,為20.4 HU。C組僅直徑6 mm的囊腫在125 HU和240 HU揹景濃度下有假性彊化。囊腫假性彊化受揹景濃度(F=17.587,P<0.01)和囊腫直徑(F=4.214,P<0.05)較大,揹景濃度越高,直徑越小,假性彊化越明顯。隨著管電流增加,CT容積劑量指數增加,假性彊化值越來越小,但各組中不同揹景濃度及不同直徑的囊腫假性彊化齣現幾率無明顯規律。結論增加CT掃描管電流不能完全消除囊腫假性彊化的產生。較高的揹景濃度和較小的囊腫直徑是產生假性彊化的重要因素。但增加管電流可以在一定程度上減少假性彊化髮生的幾率。對于體重較重者,適噹增加管電流以改善圖像質量、減少腎囊腫假性彊化髮生的可能是必要的。
목적:통과모의단순성신낭종적체모모형,평고관전류대신낭종가성강화적영향。재료여방법사용10%포도당액급일정농도적함전용액,분별모의평소、중등강화급최대강화정도신실질배경농도。낭종직경분별위6 mm、10 mm、15 mm,의거관전류불동분위A조119 mAs、B조178 mAs、C조297 mAs,관전압균위120 kV。이CT증가치10 HU위림계치,평고불동조건하낭종유무가성강화。결과 A조부재240 HU배경농도하출현가성강화,차직경6 mm적낭종최현저,위21 HU。B조직경10 mm화6 mm적낭종재180 HU화240 HU배경하균출현가성강화,차치최대위240 HU직경6 mm적낭종,위20.4 HU。C조부직경6 mm적낭종재125 HU화240 HU배경농도하유가성강화。낭종가성강화수배경농도(F=17.587,P<0.01)화낭종직경(F=4.214,P<0.05)교대,배경농도월고,직경월소,가성강화월명현。수착관전류증가,CT용적제량지수증가,가성강화치월래월소,단각조중불동배경농도급불동직경적낭종가성강화출현궤솔무명현규률。결론증가CT소묘관전류불능완전소제낭종가성강화적산생。교고적배경농도화교소적낭종직경시산생가성강화적중요인소。단증가관전류가이재일정정도상감소가성강화발생적궤솔。대우체중교중자,괄당증가관전류이개선도상질량、감소신낭종가성강화발생적가능시필요적。
PurposeTo evaluate the effect of tube current on the pseudo-enhancement of renal cyst by simulating the phantom model of simple renal cyst.Materials and Methods 10% glucose and iodine solution with a certain concentration was used to simulate the renal parenchymal background concentration in plain scan, moderate enhancement and maximum enhancement respectively. The diameters of the cysts were 6 mm, 10 mm and 15 mm, respectively, and the cysts were divided into three groups according to different tube current: 119 mAs (group A), 178 mAs (group B) and 297 mAs (group C) while the tube voltage were all 120 kV. Whether pseudo-enhancement exists in cyst under different conditions was determined using an increase of CT value of 10 HU as the critical value. Results In group A, there was pseudo enhancement at the 240 HU background, and it was most significant with the diameter of 6 mm, which was 21 HU. In group B, pseudo-enhancement occurred in cysts with diameter of both 10 mm and 6 mm under the background of 180 HU and 240 HU, moreover, the biggest difference was 20.4 HU and it occurred in cyst with diameter of 6 mm under the background of 240 HU. In group C, pseudo-enhancement only occurred in cyst with diameter of 6 mm under the condition of 125 HU and 240 HU background concentration. Background concentration (F=17.587, P<0.01) and cyst diameter (F=4.214,P<0.05) had greater impact on cyst pseudo-enhancement, the higher the background concentration and smaller the diameter, more significantly the pseudo-enhancement would occur. With the increase of the tube current, the CT volume dose index increased, and the pseudo enhancement value was smaller, but there was no obvious regularity of pseudo-enhancement occurrence rate in cysts with different background concentration and diameter in each group.Conclusion The increase of tube current cannot completely eliminate cyst pseudo-enhancement. High background concentration and small diameter cyst are important factors in pseudo-enhancement. However, increasing the tube current can reduce the probability of occurrence of pseudo-enhancement to some extent. For those with heavier body weight, it might be necessary to increase the tube current to improve image quality and reduce the occurrence of renal cyst pseudo-enhancement.